General rightsIt is not permitted to download or to forward/distribute the text or part of it without the consent of the author(s) and/or copyright holder(s), other than for strictly personal, individual use, unless the work is under an open content license (like Creative Commons). Disclaimer/Complaints regulationsIf you believe that digital publication of certain material infringes any of your rights or (privacy) interests, please let the Library know, stating your reasons. In case of a legitimate complaint, the Library will make the material inaccessible and/or remove it from the website. Please Ask the Library: http://uba.uva.nl/en/contact, or a letter to: Library of the University of Amsterdam, Secretariat, Singel 425, 1012 WP Amsterdam, The Netherlands. You will be contacted as soon as possible. Abstract. We characterize T-and B-lymphocytes from several donors, determining cell diameter, ratio of nucleus to cell diameter, and refractive index of the nucleus and cytoplasm for each individual cell. We measure light-scattering profiles with a scanning flow cytometer and invert the signals using a coated sphere as an optical model of the cell and by relying on a global optimization technique. The main difference in morphology of T-and B-lymphocytes is found to be the larger mean diameters of the latter. However, the difference is smaller than the natural biological variability of a single cell. We propose nuclear inhomogeneity as a possible reason for the deviation of measured light-scattering profiles from real lymphocytes from those obtained from the coated sphere model. © 2009 Society of Photo-Optical Instrumentation Engineers.
We introduce a novel approach for determination of volume and shape of individual blood platelets modeled as an oblate spheroid from angle-resolved light scattering with flow-cytometric technique. The light-scattering profiles (LSPs) of individual platelets were measured with the scanning flow cytometer and the platelet characteristics were determined from the solution of the inverse light-scattering problem using the precomputed database of theoretical LSPs. We revealed a phenomenon of parameter compensation, which is partly explained in the framework of anomalous diffraction approximation. To overcome this problem, additional a priori information on the platelet refractive index was used. It allowed us to determine the size of each platelet with subdiffraction precision and independent of the particular value of the platelet aspect ratio. The shape (spheroidal aspect ratio) distributions of platelets showed substantial differences between native and activated by 10 μM adenosine diphosphate samples. We expect that the new approach may find use in hematological analyzers for accurate measurement of platelet volume distribution and for determination of the platelet activation efficiency.
Importance of microparticles (MPs), also regarded as extracellular vesicles, in many physiological processes and clinical conditions motivates one to use the most informative and precise methods for their characterization. Methods based on individual particle analysis provide statistically reliable distributions of MP population over characteristics. Although flow cytometry is one of the most powerful technologies of this type, the standard forward-versus-side-scattering plots of MPs and platelets (PLTs) overlap considerably because of similarity of their morphological characteristics. Moreover, ordinary flow cytometry is not capable of measurement of size and refractive index (RI) of MPs. In this study, we 1) employed the potential of the scanning flow cytometer (SFC) for identification and characterization of MPs from light scattering; 2) suggested the reference method to characterize MP morphology (size and RI) with high precision; and 3) determined the lowest size of a MP that can be characterized from light scattering with the SFC. We equipped the SFC with 405 and 488 nm lasers to measure the light-scattering profiles and side scattering from MPs, respectively. The developed two-stage method allowed accurate separation of PLTs and MPs in plateletrich plasma. We used two optical models for MPs, a sphere and a bisphere, in the solution of the inverse light-scattering problem. This solution provides unprecedented precision in determination of size and RI of individual spherical MPs-median uncertainties (standard deviations) were 6 nm and 0.003, respectively. The developed method provides instrument-independent quantitative information on MPs, which can be used in studies of various factors affecting MP population. V C 2015 International Society for Advancement of Cytometry
Chylomicrons (CMs) are lipoprotein particles circulating in blood and transporting dietary lipids. Optically speaking, CMs are small compared to the wavelength of visible light and widely distributed by the size and refractive index (RI). Consequently, intensity of light scattered by the CMs scales with up to the sixth power of their size, hampering simultaneous analysis of 60 and 600 nm CMs. We present an accurate method for quantitative characterization of large-size CM subpopulation by the distributions over size and RI. For the first time the CM characteristics have been determined at a single particle level based on angle-resolved light-scattering measurements. We applied the developed method to 2 key processes relating to CM metabolism, namely in vivo dynamics of CMs in blood plasma after a meal and in vitro lipolysis of CMs by the lipoprotein lipase in postheparin plasma. We have observed the substantial variations in CM concentration, size and RI distributions. This opens the way for a multitude of medical applications involving screening of CM metabolism, which we exemplified by revealing large differences in CM characteristics after a 12-hour fast between a healthy volunteer and a patient with atherosclerosis.
Abstract:We propose a method for characterization of mature red blood cells (RBCs) morphology, based on measurement of light-scattering patterns (LSPs) of individual RBCs with the scanning flow cytometer and on solution of the inverse light-scattering (ILS) problem for each LSP. We considered a RBC shape model, corresponding to the minimal bending energy of the membrane with isotropic elasticity, and constructed an analytical approximation, which allows rapid simulation of the shape, given the diameter and minimal and maximal thicknesses. The ILS problem was solved by the nearest-neighbor interpolation using a preliminary calculated database of 250,000 theoretical LSPs. For each RBC in blood sample we determined three abovementioned shape characteristics and refractive index, which also allows us to calculate volume, surface area, sphericity index, spontaneous curvature, hemoglobin concentration and content. ©2016 Optical Society of America
We instrumentally, theoretically, and experimentally demonstrate a new approach for characterization of nonspherical individual particles from light scattering. Unlike the original optical scheme of the scanning flow cytometer that measures an angle-resolved scattering corresponding in general to S 11 element of the light-scattering matrix, the modernized instrument allows us to measure the polarized light-scattering profile of individual particles simultaneously. Theoretically, the polarized profile is expressed by the combination of a few light-scattering matrix elements. This approach supports us with additional independent data to characterize a particle with a complex shape and an internal structure. Applicability of the new method was demonstrated from analysis of polymer bispheres. The bisphere characteristics, sizes, and refractive indices of the each sphere composing the bisphere were successfully retrieved from the solution of the inverse light-scattering problem. The solution provides determination of the Eulerian angles, which describe the orientation of the bispheres relatively to direction of the incident laser beam and detecting polarizer of the optical system. The both ordinary and polarized profiles show a perfect agreement with T-matrix simulation resulting to 50-nm precision for sizing of bispheres. ' 2011 International Society for Advancement of Cytometry
Flow cytometry method (FCM) is widely used for analysis of cell-derived microparticles (MPs). Numerous efforts are currently aimed to standardize these measurements among different instruments. We push the FCM characterization of MPs to the limit based on rigorous simulation of measured signals. We measured forward- and side-scatter (FSC/SSC) signals and angle-resolved light-scattering profiles (LSPs) of polystyrene microspheres and MPs, including their aggregates, using a scanning flow cytometer (SFC). We used the Mie theory to (1) accurately evaluate instrument detection limits; (2) construct FSC/SSC gates for MPs in absolute scales of size and refractive index (RI); and (3) determine size and RI of individual spherical MPs. LSPs were used for advanced characterization, including differentiation of spherical and nonspherical particles. The proposed absolute FSC/SSC gating is naturally standardized for any FCM instrument, given the knowledge of its optical system and leads to instrument-independent analysis of MPs. The inverse Mie problem has a unique solution only for some regions of size and RI and uncertainties rapidly increase with decreasing size and RI. The developed methods are applicable to any flow cytometer, but are limited by assumption of particle sphericity. The latter can be relaxed only if additional signals, such as LSP, are measured.
Whereas modern automated blood cell analyzers measure the volume of individual red blood cells (RBCs), leading to four RBC indices (mean corpuscular volume, MCV; mean corpuscular hemoglobin, MCH; mean corpuscular hemoglobin concentration, MCHC; red cell distribution width, and RDW), the RBC shape has not been assessed by clinical screening tools. We applied the scanning flow cytometer (SFC) for complete characterization of intact RBC morphology in terms of diameter, maximal and minimal thicknesses, volume, surface area, sphericity index, spontaneous curvature, hemoglobin concentration, and content. The above-mentioned individual RBC characteristics were measured without fluorescent markers and other chemicals by a SFC equipped only with 660 nm laser for RBC illumination and single detector for measurement of angle-resolved light scattering. The distributions over all RBC characteristics were constructed and processed statistically to form the novel 31 RBC indices for 22 donor samples. Our results confirm the possibility of precise, label-free, enhanced morphological analysis of individual intact RBCs with compact single-detector flow cytometer. Detailed characterization of RBCs with high statistics and precision can be used to increase the value of screening examinations and to reveal pathologies accompanied by abnormality of RBC shape. © 2017 International Society for Advancement of Cytometry.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.