This study established a comprehensive approach to monitoring UVR magnitude from Shield Metal Arc Welding (SMAW) processing and quantified the effective exposure based on measured data. The irradiances from welding UVR were calculated with biological effective parameter (Slambda) for human exposure assessment. The spectral weighting function for UVR measurement and evaluation followed the American Conference of Governmental Industrial Hygienists (ACGIH) guidelines. Arc welding processing scatters bright light with UVR emission over the full UV spectrum (UVA, UVB, and UVC). The worst case of effective irradiance from a 50 cm distance arc spot with a 200 A electric current and an electrode E6011 (4 mm) is 311.0 microW cm(-2) and has the maximum allowance time (Tmax) of 9.6 s. Distance is an important factor affecting the irradiance intensity. The worst case of the effective irradiance values from arc welding at 100, 200, and 300 cm distances are 76.2, 16.6, and 12.1 microW cm(-2) with Tmax of 39.4, 180.7, and 247.9 s, respectively. Protective materials (glove and mask) were demonstrated to protect workers from hazardous UVR exposure. From this study, the methodology of UVR monitoring in SMAW processing was developed and established. It is recommended that welders should be fitted with appropriate protective materials for protection from UVR emission hazards.
The purpose of this study is to evaluate the non-ionizing radiation (NIR) exposure, especially optical radiation levels, and potential health hazard from aluminum arc welding processes based on the American Conference of Governmental Industrial Hygienists (ACGIH) method. The irradiance from the optical radiation emissions can be calculated with various biological effective parameters [i.e., S(lambda), B(lambda), R(lambda)] for NIR hazard assessments. The aluminum arc welding processing scatters bright light with NIR emission including ultraviolet radiation (UVR), visible, and infrared spectra. The UVR effective irradiance (Eeff) has a mean value of 1,100 microW cm at 100 cm distance from the arc spot. The maximum allowance time (tmax) is 2.79 s according to the ACGIH guideline. Blue-light hazard effective irradiance (EBlue) has a mean value of 1840 microW cm (300-700 nm) at 100 cm with a tmax of 5.45 s exposure allowance. Retinal thermal hazard effective calculation shows mean values of 320 mW cm(-2) sr(-1) and 25.4 mW (cm-2) (380-875 nm) for LRetina (spectral radiance) and ERetina (spectral irradiance), respectively. From this study, the NIR measurement from welding optical radiation emissions has been established to evaluate separate types of hazards to the eye and skin simultaneously. The NIR exposure assessment can be applied to other optical emissions from industrial sources. The data from welding assessment strongly suggest employees involved in aluminum welding processing must be fitted with appropriate personal protection devices such as masks and gloves to prevent serious injuries of the skin and eyes upon intense optical exposure.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.