Abstract. The neutron time-of-flight facility n TOF features a white neutron source produced by spallation through 20 GeV/c protons impinging on a lead target. The facility, aiming primarily at the measurement of neutron-induced reaction cross sections, was operating at CERN between 2001 and 2004, and then underwent a major upgrade in 2008. This paper presents in detail all the characteristics of the new neutron beam in the currently available configurations, which correspond to two different collimation systems and two choices of neutron moderator. The characteristics discussed include the intensity and energy dependence of the neutron flux, the spatial profile of the beam, the in-beam background components and the energy resolution/broadening. The discussion of these features is based on dedicated measurements and Monte Carlo simulations, and includes estimations of the systematic uncertainties of the mentioned quantities.
We report on the measurement of the ^{7}Be(n,p)^{7}Li cross section from thermal to approximately 325 keV neutron energy, performed in the high-flux experimental area (EAR2) of the n_TOF facility at CERN. This reaction plays a key role in the lithium yield of the big bang nucleosynthesis (BBN) for standard cosmology. The only two previous time-of-flight measurements performed on this reaction did not cover the energy window of interest for BBN, and they showed a large discrepancy between each other. The measurement was performed with a Si telescope and a high-purity sample produced by implantation of a ^{7}Be ion beam at the ISOLDE facility at CERN. While a significantly higher cross section is found at low energy, relative to current evaluations, in the region of BBN interest, the present results are consistent with the values inferred from the time-reversal ^{7}Li(p,n)^{7}Be reaction, thus yielding only a relatively minor improvement on the so-called cosmological lithium problem. The relevance of these results on the near-threshold neutron production in the p+^{7}Li reaction is also discussed.
We have measured the neutron capture cross sections of the stable magnesium isotopes 24,25,26 Mg in the energy range of interest to the s process using the neutron time-of-flight facility n_TOF at CERN. Capture events from a natural metal sample and from samples enriched in 25 Mg and 26 Mg were recorded using the total energy method based on C 6 2 H 6 detectors. Neutron resonance parameters were extracted by a simultaneous resonance shape analysis of the present capture data and existing transmission data on a natural isotopic sample. Maxwellian-averaged capture cross sections for the three isotopes were calculated up to thermal energies of 100 keV and their impact on s-process analyses was investigated. At 30 keV the new values of the stellar cross section for 24 Mg, 25 Mg, and 26 Mg are 3.8±0.2 mb, 4.1±0.6 mb, and 0.14±0.01 mb, respectively.
Low-mass asymptotic giant branch stars are among the most important polluters of the interstellar medium. In their interiors, the main component (A ≳ 90) of the slow neutron capture process (the s-process) is synthesized, the most important neutron source being the 13C(α,n)16O reaction. In this paper, we review its current experimental status, discussing possible future synergies between some experiments currently focused on the determination of its rate. Moreover, in order to determine the level of precision needed to fully characterize this reaction, we present a theoretical sensitivity study, carried out with the FUNS evolutionary stellar code and the NEWTON post-process code. We modify the rate up to a factor of 2 with respect to a reference case. We find that variations of the 13C(α,n)16O rate do not appreciably affect s-process distributions for masses above 3 M ⊙ at any metallicity. Apart from a few isotopes, in fact, the differences are always below 5%. The situation is completely different if some 13C burns in a convective environment: this occurs in FUNS models with M < 3 M ⊙ at solar-like metallicities. In this case, a change of the 13C(α,n)16O reaction rate leads to nonnegligible variations of the element surface distribution (10% on average), with larger peaks for some elements (such as rubidium) and neutron-rich isotopes (such as 86Kr and 96Zr). Larger variations are found in low-mass, low-metallicity models if protons are mixed and burned at very high temperatures. In this case, the surface abundances of the heavier elements may vary by more than a factor of 50.
Abstract. Cross section measurements have been performed at the time-of-flight facility GELINA to determine the average capture cross section for 197 Au in the energy region between 3.5 keV and 84 keV. Prompt γ-rays, originating from neutron-induced capture events, were detected by two C 6D6 liquid scintillators. The sample was placed at about 13 m distance from the neutron source. The total energy detection principle in combination with the pulse height weighting technique was applied. The energy dependence of the neutron flux was measured with a double Frisch-gridded ionization chamber based on the 10 B(n, α) reaction. The data have been normalized to the well-isolated and saturated197 Au resonance at 4.9 eV. Special care was taken to reduce bias effects due to the weighting function, normalization, dead time and background corrections. The total uncertainty due to normalization, neutron flux and weighting function is 1.0%. An additional uncertainty of 0.5% results from the correction for self-shielding and multiple interaction events. Fluctuations due to resonance structures have been studied by complementary measurements at a 30 m flight path station. The results reported in this work deviate systematically by more than 5% from the cross section that is recommended as a reference for astrophysical applications. They are about 2% lower compared to an evaluation of the 197 Au(n, γ) cross section, which was based on a least squares fit of experimental data available in the literature prior to this work. The average capture cross section as a function of neutron energy has been parameterized in terms of average resonance parameters. Maxwellian average cross sections at different temperatures have been calculated.
The n_TOF Collaboration has built and commissioned a high-performance detector for (n, gamma) measurements called the Total Absorption Calorimeter (TAC). The TAC was especially designed for measuring neutron capture cross-sections of low-mass and/or radioactive samples with the accuracy required for nuclear technology and stellar nucleosynthesis. We present a detailed description of the TAC and discuss its overall performance in terms of energy and time resolution, background discrimination, detection efficiency and neutron sensitivity. (C) 2009 Elsevier B.V. All rights reserved
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
334 Leonard St
Brooklyn, NY 11211
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.