The practice of determining acid concentrations by titrations has remained unchanged for more than a century. We introduce a new approach to the determination of acid concentrations based on cation exchange chromatography. We demonstrate the ability of sulfonated styrene-divinylbenzene based stationary phases to separate the hydrogen ion from other monovalent cations. The eluent is a dilute solution of a neutral salt, sometimes containing a small concentration of the corresponding acid, e.g., sodium ethanesulfonate, pH adjusted with ethanesulfonic acid. The high equivalent conductance (approximately 350 S.cm2/equiv) of H+ and relatively low eluent concentration allows sensitive conductometric detection of H+, down to the 50 microM level under favorable conditions. The conductometric response to H+ can be linear over a wide range of H+ concentrations, from sub-millimolar to several molar concentrations. The system allows the rapid quantitation of strong acids; weak acids can also be determined depending on pKa and injected concentration. The determinations of several strong and weak acids are presented along with factors that govern their chromatographic analysis.
Interest in possible sources of perchlorate (ClO4) that could lead to environmental release has been heightened since the Environmental Protection Agency placed this anion on its Contaminant Candidate List for drinking water. Although recent investigations have suggested that fertilizers are minor contributors to environmental perchlorate contamination overall, there is still interest in screening commercial products for possible contamination and quantitating perchlorate when it is found. Ion chromatography (IC) has been used for this application owing to its speed, low detection limits, widespread availability, and moderate ruggedness relative to other techniques. However, fertilizer matrixes complicate the IC analysis relative to potable water matrixes. In this study, the performance of poly(vinyl alcohol) gel resin IC columns (100 mm and 150 mm) was evaluated for fertilizer matrixes using method EPA/600/R-01/026. The NaOH eluent included an organic salt, sodium 4-cyanophenoxide. Detection was by suppressed conductivity. A set of 55 different field samples representing 48 products and previously used by the EPA to assess occurrence of perchlorate in fertilizers (EPA/600/R-01/049) was reanalyzed on the 150 mm column. The 100 mm column was used to further investigate the positive hits. Both columns gave satisfactory performance in fertilizer matrixes, with spike recoveries (+/- 15%), assured reporting levels (0.5-225 microg g(-1) except for one at 1,000 microg g(-1)), accuracy (relative error < 30% always and most < 15%), and precision [injection-to-injection reproducibility < 3% relative standard deviation (RSD)] comparable to those reported in other studies. Performance did not vary substantially between column lengths. Lastly, the results of this investigation provided further evidence in support of the conclusions that had been reached previously by the EPA on the occurrence of perchlorate in fertilizers.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.