IntroductionMicro-invasive glaucoma surgical implantation of trabecular micro-bypass stents, previously shown to be safe and effective for open-angle glaucoma (OAG) subjects during cataract surgery, was considered for evaluation as a sole procedure. The aim of this study was to evaluate the safety and intraocular pressure (IOP)-lowering efficacy after ab interno implantation of two Glaukos Trabecular Micro-Bypass iStent inject second generation devices in subjects with OAG. This study was performed at sites in France, Germany, Italy, Republic of Armenia, and Spain.MethodsIn this pan-European, multi-center prospective, post-market, unmasked study, 99 patients with OAG on at least two topical ocular hypotensive medications who required additional IOP lowering to control glaucoma disease underwent implantation of two GTS400 stents in a stand-alone procedure. Patients were qualified if they presented with preoperative mean IOP between 22 and 38 mmHg after medication washout. Postoperatively, subjects were assessed at Day 1, Months 1, 3, 6, 7, 9, and 12. IOP, medication use and safety were assessed at each visit.ResultsSixty-six percent of subjects achieved IOP ≤18 mmHg at 12 months without medication, and 81% of subjects achieved Month 12 IOP ≤ 18 mmHg with either a single medication or no medication. Mean baseline washout IOP values decreased by 10.2 mmHg or 39.7% from 26.3 (SD 3.5) mmHg to 15.7 (SD 3.7) mmHg at Month 12. Mean IOP at 12 months was 14.7 (SD 3.1) mmHg in subjects not using ocular hypotensive medications. Reduction from preoperative medication burden was achieved in 86.9% of patients, including 15.2% with reduction of one medication and 71.7% with reduction of two or more medications. Postoperative complications occurred at a low rate and resolved without persistent effects.ConclusionIn this series, implantation of two trabecular micro-bypass second generation stents in subjects with OAG resulted in IOP and medication reduction and favorable safety outcomes.Electronic supplementary materialThe online version of this article (doi:10.1007/s12325-014-0095-y) contains supplementary material, which is available to authorized users.
Background Though several procedures of IOL implantation have been described (sutured scleral fixation, intra-scleral fixation, angle-supported anterior chamber, and anterior chamber or retropupillary iris-claw IOLs), there are no randomized trials which are comparing different techniques. Hence, the surgical treatment of aphakia still remains controversial and challenging. The purpose of this study was to compare the long-term efficacy and the rate of complications of anterior versus posterior Iris-claw intraocular lenses (IOL) implantation to correct for the treatment of aphakia without sufficient capsule support. Methods and findings Consecutive eyes having secondary implantation of aphakic iris-fixated IOLs with a follow-up of at least 5 years were considered. Mean correct distance visual acuity (CDVA) changes, percentage of eyes with CDVA improvement, mean corneal endothelial cell density (CECD) loss and the rate of other complications were used for statistical analysis. The study evaluated a total of 180 eyes (Group A: 87 anterior chamber iris-claw fixation, Group B: 93 retropupillary iris-claw implantation) of 180 consecutive different patients, with aphakia of various reasons. CDVA improved significantly in both groups after surgery (P<0.001, ANOVA), and was remarkably higher than baseline in both groups from first week and during the entire follow-up (P<0.001, Tukey’s Honest Significant Difference). There was no statistically significant difference in CDVA between the two groups during each follow-up visits (P = NS, unpaired t-test) and in the CDVA improvement percentage between the two groups (P = 0.882, Chi-square test). No significant changes in CECD were noted after surgery in both groups (ANOVA Group A: P = 0.067, Group B: P = 0.330P). No intra-operative complications occurred in both groups. There was no statistically significant difference in the rate of complications between the two groups (P = NS, Chi-square test), except for pigment precipitates which were higher in Group A (P<0.05, Chi-square test). Conclusions Five-year follow-up shows that secondary implantation of aphakic IOLs is effective and safe for the correction treatment of aphakia in eyes without capsule support.
Aims: To present an authoritative, universal, easy-to-use morphologic classification of diabetic maculopathy based on spectral domain optical coherence tomography. Methods: The first draft of the project was developed based on previously published classifications and a literature search regarding the spectral domain optical coherence tomography quantitative and qualitative features of diabetic maculopathy. This draft was sent to an international panel of retina experts for a first revision. The panel met at the European School for Advanced Studies in Ophthalmology headquarters in Lugano, Switzerland, and elaborated the final document. Results: Seven tomographic qualitative and quantitative features are taken into account and scored according to a grading protocol termed TCED-HFV, which includes foveal thickness (T), corresponding to either central subfoveal thickness or macular volume, intraretinal cysts (C), the ellipsoid zone (EZ) and/or external limiting membrane (ELM) status (E), presence of disorganization of the inner retinal layers (D), number of hyperreflective foci (H), subfoveal fluid (F), and vitreoretinal relationship (V). Four different stages of the disease, that is, early diabetic maculopathy, advanced diabetic maculopathy, severe diabetic maculopathy, and atrophic maculopathy, are based on the first four variables, namely the T, C, E, and D. The different stages reflect progressive severity of the disease. Conclusion: A novel grading system of diabetic maculopathy is hereby proposed. The classification is aimed at providing a simple, direct, objective tool to classify diabetic maculopathy (irrespective to the treatment status) even for non-retinal experts and can be used for therapeutic and prognostic purposes, as well as for correct evaluation and reproducibility of clinical investigations.
PurposeThe purpose of this study was to compare outcomes of subjects with open-angle glaucoma (OAG) not controlled on one medication who underwent either implantation of two iStent inject® trabecular micro-bypass devices or received medical therapy consisting of a fixed combination of latanoprost/timolol.Patients and methodsOf 192 subjects who qualified for the study and were enrolled, 94 were randomized to surgery with implantation of two iStent inject® devices in the treated eye and 98 to receive medical therapy.ResultsAt the month 12 visit, 94.7% of eyes (89/94) in the stent group reported an unmedicated intraocular pressure (IOP) reduction of ≥20% versus baseline unmedicated IOP, and 91.8% of eyes (88/98) in the medical therapy group reported an IOP reduction ≥20% versus baseline unmedicated IOP. A 17.5% between-group treatment difference in favor of the iStent inject group was statistically significant (P=0.02) at the ≥50% level of IOP reduction. An IOP ≤18 mmHg was reported in 92.6% of eyes (87/94) in the iStent inject group and 89.8% of eyes (88/98) in the medical therapy group. Mean (standard deviation) IOP decreases from screening of 8.1 (2.6) mmHg and 7.3 (2.2) mmHg were reported in the iStent inject and medical therapy groups, respectively. A high safety profile was also noted in this study in both the iStent inject and medical therapy groups, as measured by stable best corrected visual acuity, cup-to-disc ratio, and adverse events.ConclusionThese data show that the use of iStent inject is at least as effective as two medications, with the clinical benefit of reducing medication burden and assuring continuous treatment with full compliance to implant therapy as well as having a highly favorable safety profile.
Tumors of the lacrimal drainage system are rare, but potentially life-threatening. They comprise a large and variable spectrum of entities grouped into three major categories of primary epithelial, primary nonepithelial and inflammatory lesions. The most common primary epithelial tumors include papilloma, squamous cell carcinoma and transitional cell carcinoma, the most frequent primary nonepithelial tumors fibrous histiocytoma, malignant lymphoma and malignant melanoma, and the most common inflammatory lesions sarcoidosis, Wegener granulomatosis and pyogenic granuloma. This review outlines the incidence, types, management and prognosis of tumors affecting the lacrimal drainage system.
Trace elements might play a role in the complex multifactorial pathogenesis of age-related macular degeneration (AMD). The aim of this study was to measure alterations of trace elements levels in aqueous humor of patients with non-exsudative (dry) AMD.For this pilot study, aqueous humor samples were collected from patients undergoing cataract surgery. 12 patients with dry AMD (age 77.9±6.62, female 8, male 4) and 11 patients without AMD (age 66.6±16.7, female 7, male 4) were included. Aqueous levels of cadmium, cobalt, copper, iron, manganese, selenium, and zinc were measured by use of Flow-Injection-Inductively-Coupled-Plasma-Mass-Spectrometry (FI-ICP-MS), quality controlled with certified standards.Patients with AMD had significantly higher aqueous humor levels of cadmium (median: 0.70 µmol/L, IQR: 0.40–0.84 vs. 0.06 µmol/L; IQR: 0.01–.018; p = 0.002), cobalt (median: 3.1 µmol/L, IQR: 2.62–3.15 vs. 1.17 µmol/L; IQR: 0.95–1.27; p<0.001), iron (median: 311 µmol/L, IQR: 289–329 vs. 129 µmol/L; IQR: 111–145; p<0.001) and zinc (median: 23.1 µmol/L, IQR: 12.9–32.6 vs. 5.1 µmol/L; IQR: 4.4–9.4; p = 0.020) when compared with patients without AMD. Copper levels were significantly reduced in patients with AMD (median: 16.2 µmol/L, IQR: 11.4–31.3 vs. 49.9 µmol/L; IQR: 32.0–.142.0; p = 0.022) when compared to those without. No significant differences were observed in aqueous humor levels of manganese and selenium between patients with and without AMD. After an adjustment for multiple testing, cadmium, cobalt, copper and iron remained a significant factor in GLM models (adjusted for age and gender of the patients) for AMD.Alterations of trace element levels support the hypothesis that cadmium, cobalt, iron, and copper are involved in the pathogenesis of AMD.
Purpose. To evaluate the indications, refraction, and visual and safety outcomes of iris-claw intraocular lens implanted retropupillary with sutureless technique during primary or secondary operation. Methods. Retrospective study of case series. The Haigis formula was used to calculate intraocular lens power. In all cases the wound was closed without suturing. Results. The study comprised 47 eyes. The mean follow-up time was 15.9 months (SD 12.2). The mean preoperative CDVA was 0.25 (SD 0.21). The final mean CDVA was 0.46 (SD 0.27). No hypotony or need for wound suturing was observed postoperatively. Mean postoperative refractive error was −0.27 Dsph (−3.87 Dsph to +2.85 Dsph; median 0.0, SD 1.28). The mean postoperative astigmatism was −1.82 Dcyl (min −0.25, max −5.5; median −1.25, SD 1.07). Postoperative complications were observed in 10 eyes. The most common complication was ovalization of the iris, which was observed in 8 eyes. The mean operation time was 35.9 min (min 11 min, max 79 min; median 34, SD 15.4). Conclusion. Retropupilary iris-claw intraocular lens (IOL) implantation with sutureless wound closing is an easy and fast method, ensuring good refractive outcome and a low risk of complication. The Haigis formula proved to be predictable in postoperative refraction.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.