IntroductionMicro-invasive glaucoma surgical implantation of trabecular micro-bypass stents, previously shown to be safe and effective for open-angle glaucoma (OAG) subjects during cataract surgery, was considered for evaluation as a sole procedure. The aim of this study was to evaluate the safety and intraocular pressure (IOP)-lowering efficacy after ab interno implantation of two Glaukos Trabecular Micro-Bypass iStent inject second generation devices in subjects with OAG. This study was performed at sites in France, Germany, Italy, Republic of Armenia, and Spain.MethodsIn this pan-European, multi-center prospective, post-market, unmasked study, 99 patients with OAG on at least two topical ocular hypotensive medications who required additional IOP lowering to control glaucoma disease underwent implantation of two GTS400 stents in a stand-alone procedure. Patients were qualified if they presented with preoperative mean IOP between 22 and 38 mmHg after medication washout. Postoperatively, subjects were assessed at Day 1, Months 1, 3, 6, 7, 9, and 12. IOP, medication use and safety were assessed at each visit.ResultsSixty-six percent of subjects achieved IOP ≤18 mmHg at 12 months without medication, and 81% of subjects achieved Month 12 IOP ≤ 18 mmHg with either a single medication or no medication. Mean baseline washout IOP values decreased by 10.2 mmHg or 39.7% from 26.3 (SD 3.5) mmHg to 15.7 (SD 3.7) mmHg at Month 12. Mean IOP at 12 months was 14.7 (SD 3.1) mmHg in subjects not using ocular hypotensive medications. Reduction from preoperative medication burden was achieved in 86.9% of patients, including 15.2% with reduction of one medication and 71.7% with reduction of two or more medications. Postoperative complications occurred at a low rate and resolved without persistent effects.ConclusionIn this series, implantation of two trabecular micro-bypass second generation stents in subjects with OAG resulted in IOP and medication reduction and favorable safety outcomes.Electronic supplementary materialThe online version of this article (doi:10.1007/s12325-014-0095-y) contains supplementary material, which is available to authorized users.
Intacs provided better results in visual acuity and corneal topography quality and significantly reduced the spherical equivalent in eyes with keratoconus with relatively low mean K values (< or =53 D) and a relatively low spherical equivalent. In advanced keratoconus (mean K-reading > or =55 D), poor results can be anticipated.
PurposeThe purpose of this study was to compare outcomes of subjects with open-angle glaucoma (OAG) not controlled on one medication who underwent either implantation of two iStent inject® trabecular micro-bypass devices or received medical therapy consisting of a fixed combination of latanoprost/timolol.Patients and methodsOf 192 subjects who qualified for the study and were enrolled, 94 were randomized to surgery with implantation of two iStent inject® devices in the treated eye and 98 to receive medical therapy.ResultsAt the month 12 visit, 94.7% of eyes (89/94) in the stent group reported an unmedicated intraocular pressure (IOP) reduction of ≥20% versus baseline unmedicated IOP, and 91.8% of eyes (88/98) in the medical therapy group reported an IOP reduction ≥20% versus baseline unmedicated IOP. A 17.5% between-group treatment difference in favor of the iStent inject group was statistically significant (P=0.02) at the ≥50% level of IOP reduction. An IOP ≤18 mmHg was reported in 92.6% of eyes (87/94) in the iStent inject group and 89.8% of eyes (88/98) in the medical therapy group. Mean (standard deviation) IOP decreases from screening of 8.1 (2.6) mmHg and 7.3 (2.2) mmHg were reported in the iStent inject and medical therapy groups, respectively. A high safety profile was also noted in this study in both the iStent inject and medical therapy groups, as measured by stable best corrected visual acuity, cup-to-disc ratio, and adverse events.ConclusionThese data show that the use of iStent inject is at least as effective as two medications, with the clinical benefit of reducing medication burden and assuring continuous treatment with full compliance to implant therapy as well as having a highly favorable safety profile.
The Orbscan II pachymetry measurements correlated with the ultrasound measurements in eyes with clear corneas. Haze after PRK decreased the Orbscan pachymetry.
Introduction: This study evaluates long-term outcomes of two trabecular micro-bypass stents, one suprachoroidal stent, and postoperative prostaglandin in eyes with refractory open angle glaucoma (OAG). Methods: Prospective ongoing 5-year study of 80 eligible subjects (70 with 4-year follow-up) with OAG and IOP C 18 mmHg after prior
Results indicate that contact lens fitting is a good-and sometimes the only-alternative for patients with induced irregular astigmatism. Rigid gas-permeable contact lenses provided the best visual performance and patient tolerance.
Objectives
To investigate the associations between different single-piece monofocal intraocular lenses (IOLs) and neodymium-doped yttrium aluminum garnet laser (Nd:YAG) capsulotomy incidence 3 years after cataract surgery in a Spanish cohort.
Methods
This is a longitudinal retrospective cohort study. Data were extracted from the electronic medical records of two large regional hospitals in Spain. Patients aged ≥65 years receiving cataract surgery with placement of five different IOLs and with ≥6 months of baseline data were included. We report the Nd:YAG capsulotomy incidence 3 years post cataract surgery, and the survival plot over the 3 years of follow-up time. The associated adjusted (age, gender, and diabetic retinopathy) multivariate analysis with odds ratios (ORs) and 95% CIs is also presented.
Results
The cohort (53% female, mean age 75 ± 5.9 years) included 14,519 eyes (Alcon AcrySof = 2968, AJL LLASY60 = 1776, Medicontur Bi-flex = 5176, Zeiss Asphina = 4478, and IOL Tech Stabibag = 121). Of these, 8293 were retained until 3-year follow-up. At 3 years after cataract surgery, the Nd:YAG capsulotomy incidence was 5% for Alcon AcrySof, while it ranged from 21.2% to 31.1% for the other IOLs (p < 0.0001 for each comparison). The odds for Nd:YAG capsulotomy were significantly higher (p < 0.0001) for other IOLs compared with those of Alcon AcrySof (ORs = 8.85, 5.86, 5.74, 5.21 for AJL LLASY60, Medicontur Bi-flex, IOL Tech Stabibag, and Zeiss Asphina, respectively).
Conclusions
The lower Nd:YAG capsulotomy rates for Alcon AcrySof IOLs compared to the other IOLs support the importance of lens choice in reducing patient burden and treatment costs.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.