The questionnaires were easy to complete and changes in sexuality and information needs were identified. The NSCS-CHF needs further validation as a research instrument. Healthcare professionals can use both questionnaires to bring up the topic of sexuality and to identify topics that require further discussion or counselling with patients and partners.
Background: The implantable cardioverter defibrillator (ICD) might give unwanted shocks in the last month of life. Guidelines recommend deactivation of the ICD prior to death. Aims: The aims of this study were to examine trends in time (2007–2016) in how and when decisions are made about ICD deactivation, and to examine patient- and disease-related factors which may have influenced these decisions. In addition, care and ICD shock frequency in the last month of life of ICD patients are described. Methods: Medical records of a sample of deceased patients who had their ICD implanted in 1999–2015 in a Dutch university ( n = 308) or general ( n = 72) hospital were examined. Results: Median age at death was 71 years, and 88% were male. ICD deactivation discussions increased from 6% for patients who had died between 2007 and 2009 to 35% for patients who had died between 2013 and 2016. ICD deactivation rates increased in these periods from 16% to 42%. Presence of do-not-resuscitate (DNR) orders increased from 9% to 46%. Palliative care consultations increased from 0% to 9%. When the ICD remained active, shocks were reported for 7% of patients in the last month of life. Predictors of ICD deactivation were the occurrence of ICD deactivation discussions after implantation (OR 69.30, CI 26.45–181.59), DNR order (OR 6.83, CI 4.19–11.12), do-not-intubate order (OR 6.41, CI 3.75–10.96), and palliative care consultations (OR 8.67, CI 2.76–27.21) Conclusion: ICD deactivation discussions and deactivation rates have increased since 2007. Nevertheless, ICDs remain active in the majority of patients at the end of life, some of whom experience shocks.
ObjectiveImplantable cardioverter defibrillators can treat life-threatening arrhythmias, but may negatively influence the last phase of life if not deactivated. Advance care planning conversations can prepare patients for future decision-making about implantable cardioverter defibrillator deactivation. This study aimed at gaining insight in the experiences of patients with advance care planning conversations about implantable cardioverter defibrillator deactivation.MethodsIn this qualitative study, we held five focus groups with 41 patients in total. Focus groups were audio-recorded and transcribed. Transcripts were analysed thematically, using the constant comparative method, whereby themes emerging from the data are compared with previously emerged themes.ResultsMost patients could imagine deciding to have their implantable cardioverter defibrillator deactivated, for instance because the benefits of an active device no longer outweigh the harm of unwanted shocks, when having another life-limiting illness, or when relatives would think this would be in their best interest. Some patients expressed a need for advance care planning conversations with a healthcare professional about deactivation, but few had had these. Others did not, saying they solely focused on living. Some patients were hesitant to record their preferences about deactivation in advance care directives, because they were unsure whether their current preferences would reflect future preferences.ConclusionsAlthough patients expressed a need for more information, advance care planning conversations about implantable cardioverter defibrillator deactivation seemed to be uncommon. Deactivation should be more frequently addressed by healthcare professionals, tailored to the disease stage of the patient and readiness to discuss this topic.
AimsTo describe the safety and performance of STENTYS self-expandable bare metal stents (BMS) versus paclitaxel-eluting stents (PES) in saphenous vein grafts (SVGs).Methods and ResultsA randomised controlled trial was performed in four hospitals in three European countries between December 2011 and December 2013. Patients with de novo lesions (>50% stenosis) in an SVG with a diameter between 2.5–6 mm were included. Primary endpoint was late lumen loss at 6 months. Secondary endpoints included procedural success and the occurrence of major adverse cardiac events (MACE) at 12 months. A total of 57 patients were randomised to STENTYS self-apposing BMS (n = 27) or PES (n = 30). Procedural success was obtained in 89.5%. No significant differences in late lumen loss were found between BMS and PES at 6 months (0.53 mm vs 0.47; p = 0.86). MACE rates at 12 months were comparable in both groups (BMS 22.2% vs. PES 26.7%; p = 0.70).ConclusionsTreatment of SVGs with STENTYS self-expandable stents is safe and effective. No significant differences were found in late lumen loss and MACE between BMS and PES.
Background: Little is known about the last phase of life of patients with implantable cardioverter defibrillators and the practice of advance care planning in this population. Aim: To describe the last phase of life and advance care planning process of patients with an implantable cardioverter defibrillator, and to assess relatives’ satisfaction with treatment and care. Design: Mixed-methods study, including a survey and focus group study. Setting/participants: A survey among 170 relatives (response rate 59%) reporting about 154 deceased patients, and 5 subsequent focus groups with 23 relatives. Results: Relatives reported that 38% of patients had a conversation with a healthcare professional about implantable cardioverter defibrillator deactivation. Patients’ and relatives’ lack of knowledge about device functioning and the perceived lack of time of healthcare professionals were frequently mentioned barriers to advance care planning. Twenty-four percent of patients experienced a shock in the last month of life, which were, according to relatives, distressing for 74% of patients and 73% of relatives. Forty-two to sixty-one percent of relatives reported to be satisfied with different aspects of end-of-life care, such as the way in which wishes of the patient were respected. Quality of death was scored higher for patients with a deactivated device than those with an active device (6.74 vs 5.67 on a 10-point scale, p = 0.012). Conclusions: Implantable cardioverter defibrillator deactivation was discussed with a minority of patients. Device shocks were reported to be distressing to patients and relatives. Relatives of patients with a deactivated device reported a higher quality of death compared to relatives of patients with an active device.
The implantable cardioverter defibrillator (ICD) is effective in terminating life-threatening arrhythmias. However, in the last phase of life, ICD shocks may no longer be appropriate. Guidelines recommend timely discussion with the patient regarding deactivation of the shock function of the ICD. However, research shows that such conversations are scarce, and some patients experience avoidable and distressful shocks in the final days of life. Barriers such as physicians’ lack of time, difficulties in finding the right time to discuss ICD deactivation, patients’ reluctance to discuss the topic, and the fragmentation of care, which obscures responsibilities, prevent healthcare professionals from discussing this topic with the patient. In this point-of-view article, we argue that healthcare professionals who are involved in the care for ICD patients should be better educated on how to communicate with patients about ICD deactivation and the end of life. Optimal communication is needed to reduce the number of patients experiencing inappropriate and painful shocks in the terminal stage of their lives.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.