2018
DOI: 10.1111/aor.13287
|View full text |Cite
|
Sign up to set email alerts
|

Use of a Mechanical Circulatory Support Simulation to Study Pump Interactions With the Variable Hemodynamic Environment

Abstract: The Virtual Mock Loop, a versatile virtual mock circulation loop, was developed using a lumpedparameter model of the mechanically assisted human circulatory system. Inputs allow specification of a variety of continuous-flow pumps (left, right, or biventricular assist devices) and a total artificial heart that can selfregulate between left and right pump outputs. Hemodynamic inputs were simplified using a diseasebased input panel, allowing selection of a combination of cardiovascular disease states, including s… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0

Year Published

2019
2019
2020
2020

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 8 publications
(13 citation statements)
references
References 11 publications
(29 reference statements)
0
13
0
Order By: Relevance
“…The VML software, developed in MATLAB (MathWorks, Inc., Natick, MA, USA), simulates the hemodynamics of the cardiovascular system with a lumped‐parameter model, including systemic and pulmonary circulation and cardiac four‐chamber and valve characteristics . In this study, we developed a new version of the VML specialized to simulate a CFTAH support condition (Figure ).…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…The VML software, developed in MATLAB (MathWorks, Inc., Natick, MA, USA), simulates the hemodynamics of the cardiovascular system with a lumped‐parameter model, including systemic and pulmonary circulation and cardiac four‐chamber and valve characteristics . In this study, we developed a new version of the VML specialized to simulate a CFTAH support condition (Figure ).…”
Section: Methodsmentioning
confidence: 99%
“…The VML software, developed in MATLAB (MathWorks, Inc., Natick, MA, USA), simulates the hemodynamics of the cardiovascular system with a lumped-parameter model, including systemic and pulmonary circulation and cardiac four-chamber and valve characteristics. 12 In this study, we developed a new version of the VML specialized to simulate a CFTAH support condition ( Figure 2). The development of this new model included removing the input for heart condition, as both ventricles with four valves are resected during implantation, and including the speed modulation feature of the CFTAH, adding both pulse rate and speed range, as the CFTAH is able to run with sinusoidal speed modulation.…”
Section: Virtual Mock Loop For Cftahmentioning
confidence: 99%
See 2 more Smart Citations
“…David J. Horvath et al of R1 Engineering, Euclid, OH, USA, reported on their virtual mock circulation loop to better comprehend the interactions of mechanical circulatory support pumps with more extensive combination of patient‐specific or simulation conditions than can be established by practical experimentation. Usability was an important factor in constructing computer models for research purposes, and among their primary objectives in creating this simulation model were to make it as portable and useful as possible outside the lab environment, by people not involved in the creation of its operational software.…”
Section: Cardiac Support and Blood Pumpsmentioning
confidence: 99%