Objective The Cleveland Clinic continuous-flow total artificial heart (CFTAH) is a compact, single-piece, valveless, pulsatile pump providing self-regulated hemodynamic output to left/right circulation. We evaluated chronic in vivo pump performance, physiologic and hemodynamic parameters, and biocompatibility of the CFTAH in a well-established calf model. Methods CFTAH pumps have been implanted in 17 calves total. Hemodynamics, pump performance, and device-related adverse events were evaluated during studies and at necropsy. Results In vivo experiments demonstrated good hemodynamic performance (pump flow, 7.3 ± 0.7 L/min; left atrial pressure [LAP], 16 ± 3 mm Hg; right atrial pressure [RAP], 17 ± 3 mm Hg; RAP-LAP difference, 1 ± 2 mm Hg; mean arterial pressure, 103 ± 7 mm Hg; arterial pulse pressure, 30 ± 11 mm Hg; pulmonary arterial pressure, 34 ± 5 mm Hg). The CFTAH has operated within design specifications and never failed. With ever-improving pump design, the implants have shown no chronic hemolysis. Three recent animals with the CFTAH recovered well, with no postoperative anticoagulation, during planned in vivo durations of 30, 90, and 90 days (last two were intended to be 90-day studies). All these longest-surviving cases showed good biocompatibility, with no thromboembolism in organs. Conclusions The current CFTAH has demonstrated reliable self-regulation of hemodynamic output and acceptable biocompatibility without anticoagulation throughout 90 days of chronic implantation in calves. Meeting these milestones is in accord with our strategy to achieve transfer of this unique technology to surgical practice, thus filling the urgent need for cardiac replacement devices as destination therapy.
Failure of the right ventricle represents a significant clinical problem and may have different causes, with rates varying between 5% and 50% in patients supported by a left ventricular assist device (LVAD). However, treatment options and device development for right ventricular failure (RVF) have significantly lagged behind those for LVADs. Newer technologies designed or adapted for RV support are needed to provide adequate long-term circulatory support. In this review, we discuss (1) the significance of RVF and its physiologic implications, (2) device constraints affecting treatment options for RVF, and (3) implantable VADs potentially available for RV support.
Cleveland Clinic's continuous-flow total artificial heart (CFTAH) provides systemic and pulmonary circulations using one assembly (one motor, two impellers). The right pump hydraulic output to the pulmonary circulation is self-regulated by the rotating assembly's passive axial movement in response to atrial differential pressure to balance itself to the left pump output. This combination of features integrates a biocompatible, pressure-balancing regulator with a double-ended pump. The CFTAH requires no flow or pressure sensors. The only control parameter is pump speed, modulated at programmable rates (60-120 beats/min) and amplitudes (0 to ±25%) to provide flow pulses. In bench studies, passive self-regulation (range: -5 mm Hg ≤ [left atrial pressure - right atrial pressure] ≤ 10 mm Hg) was demonstrated over a systemic/vascular resistance ratio range of 2.0-20 and a flow range of 3-9 L/min. Performance of the most recent pump configuration was demonstrated in chronic studies, including three consecutive long-term experiments (30, 90, and 90 days). These experiments were performed at a constant postoperative mean speed with a ±15% speed modulation, demonstrating a totally self-regulating mode of operation, from 3 days after implant to explant, despite a weight gain of up to 40%. The mechanism of self-regulation functioned properly, continuously throughout the chronic in vivo experiments, demonstrating the performance goals.
The new Advanced ventricular assist device (Advanced VAD) has many features such as improving pulsatility and preventing regurgitant flow during pump stoppage. The purpose of this study was to evaluate the effects of design modifications of the Advanced VAD on these features in vitro. Bench testing of four versions of the Advanced VAD was performed on a static or pulsatile mock loop with a pneumatic device. After pump performance was evaluated, each pump was run at 3000 rpm to evaluate pulse augmentation, then was stopped to assess regurgitant flow through the pump. There was no significant difference in pump performance between the pump models. The average pulse pressure in the pulsatile mock loop was 23.0, 34.0, 39.3, 33.8, and 37.3 mm Hg without pump, with AV010, AV020 3S, AV020 6S, and AV020 RC, respectively. The pulse augmentation factor was 48%, 71%, 47%, and 62% with AV010, AV020 3S, AV020 6S, and AV020 RC, respectively. In the pump stop test, regurgitant flow was −0.60 ± 0.70, −0.13 ± 0.57, −0.14 ± 0.09, and −0.18 ± 0.06 L/min in AV010, AV020 3S, AV020 6S, and AV020 RC, respectively. In conclusion, by modifying the design of the Advanced VAD, we successfully showed the improved pulsatility augmentation and regurgitant flow shut‐off features.
We report our institutional experience, with 25 consecutive patients with patent coronary artery bypass grafts (71.8+/-12.7 years), who underwent video-assisted minithoracotomic approach for mitral valve surgery. The surgical technique includes: right minithoracotomy, femoral cannulation and hypothermic ventricular fibrillation. Mean preoperative EuroSCORE was 10.2+/-2.4 and mean ejection fraction was 45+/-9%. Operative mortality was 4% (1/25). No patient required a conversion to sternotomy. Procedures performed were: mitral valve repair in 15 patients (60%), replacement in 10 (40%) and associated tricuspid repair in seven (28%). Mean blood transfusion was 1.2 package/patient. No cardiological, neurological, vascular and wound complications were observed. Postoperative major morbidity includes: severe pulmonary dysfunction in two patients (8%) and acute renal failure in one (4%). Mean ICU and hospital stay were 3.4+/-2.9 and 10.6+/-7.9 days. Echocardiographic follow-up (22.8+/-14.9 months) revealed trace or mild mitral valve regurgitation in all the mitral repair patients. When interrogated, all the surviving patients preferred the minithoracotomic approach rather than the sternotomy. In conclusion, minimally invasive right thoracotomy can be safely performed in patients with functioning coronary bypass grafts requiring mitral valve operation. Low blood transfusion, the avoidance of deep wound infection and the high patient satisfaction are the main advantages of this approach.
The VentriFlo True Pulse Pump (Design Mentor, Inc., Pelham, NH, USA) is the first blood pump designed to mimic human arterial waveforms in a standard oxygenation circuit. Our aim was to demonstrate the feasibility and safety of this pump in preparation for future studies to determine possible clinical advantages. We studied four piglets (41.4-46.2 kg): three with an implanted VentriFlo pulsatile pump and one with the nonpulsatile ROTAFLOW pump (MAQUET Holding B.V. & Co. KG, Rastatt, Germany) as a control. Hemodynamics was monitored during 6-h cardiopulmonary bypass (CPB) support and for 2 h after weaning off CPB. The VentriFlo demonstrated physiologic arterial waveforms with arterial pulse pressure of 24.6 ± 5.7 mm Hg. Pump flows (2.0 ± 0.1 L/min in ROTAFLOW; 1.9 ± 0.1 L/min in VentriFlo) and plasma free hemoglobin levels (27.9 ± 12.5 mg/dL in ROTAFLOW; 28.5 ± 14.2 mg/dL in VentriFlo) were also comparable, but systemic O extraction (as measured by arterial minus venous O saturation) registered slightly higher with the VentriFlo (63.2 ± 6.9%) than the ROTAFLOW (55.4 ± 6.5%). Histological findings showed no evidence of ischemic changes or thromboembolism. This pilot study demonstrated that the VentriFlo system generated pulsatile flow and maintained adequate perfusion of all organs during prolonged CPB.
Implantation of mechanical circulatory support devices is challenging, especially in patients with a small chest cavity. We evaluated how well the Cleveland Clinic continuous-flow total artificial heart (CFTAH) fit the anatomy of patients about to receive a heart transplant. A mock pump model of the CFTAH was rapid-prototyped using biocompatible materials. The model was brought to the operative table, and the direction, length, and angulation of the inflow/outflow ports and outflow conduits were evaluated after the recipient's ventricles had been resected. Thoracic cavity measurements were based on preoperative computed tomographic data. The CFTAH fit well in all five patients (height, 170 ± 9 cm; weight, 75 ± 24 kg). Body surface area was 1.9 ± 0.3 m2 (range, 1.6-2.1 m2). The required inflow and outflow port orientation of both the left and right housings appeared consistent with the current version of the CFTAH implanted in calves. The left outflow conduit remained straight, but the right outflow direction necessitated a 73 ± 22 degree angulation to prevent potential kinking when crossing over the connected left outflow. These data support the fact that our design achieves the proper anatomical relationship of the CFTAH to a patient's native vessels.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.