1967
DOI: 10.1002/cber.19671000506
|View full text |Cite
|
Sign up to set email alerts
|

Thioncarbonsäureester, I. Monothionmalonsäureester

Abstract: Ausgehend vom Cyanessigsaure-athylester wurden uber die Stufe der Imidsaureester-hydrochloride 1 a-f die Monothionmalonsaureester 2a-f dargestellt. Die Thionmalonsaureester unterliegen ebenso wie methylenaktive Thioamide einer Thion-Enthiol-Tautomerie. Sie werden in Gegenwart von Natriumalkoholat bevorzugt a m Schwefel alkyliert. Ihre Methylenaktivitat I l l 3 sich durch Michael-Addition und Knoevenagel-Kondensation nachweisen.Im Unterschied zu den Monothiocarbonsauren, in denen die Thiolform domi-niertW), las… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
5
0

Year Published

1967
1967
2003
2003

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 25 publications
(5 citation statements)
references
References 21 publications
0
5
0
Order By: Relevance
“…Infrared spectra were recorded on a Pye-Unicam SP3-100 or a Philips PU9706 spectrometer in chloroform unless otherwise stated. Nuclear magnetic resonance (NMR) spectra were recorded using the following instruments: 1 H spectra at 250 MHz on a Bruker WM250 PFT or at 400 MHz on a Bruker AM400 PFT; 13 C spectra on a Bruker FX90 at 22.5 MHz, a Bruker WM250 PFT at 62.5 MHz, or a Bruker AM400 PFT at 100 MHz and multiplicites were determined using DEPT sequences. NMR Spectra were recorded for solutions in deuteriochloroform with tetramethylsilane as an internal standard unless otherwise stated.…”
Section: Methodsmentioning
confidence: 99%
“…Infrared spectra were recorded on a Pye-Unicam SP3-100 or a Philips PU9706 spectrometer in chloroform unless otherwise stated. Nuclear magnetic resonance (NMR) spectra were recorded using the following instruments: 1 H spectra at 250 MHz on a Bruker WM250 PFT or at 400 MHz on a Bruker AM400 PFT; 13 C spectra on a Bruker FX90 at 22.5 MHz, a Bruker WM250 PFT at 62.5 MHz, or a Bruker AM400 PFT at 100 MHz and multiplicites were determined using DEPT sequences. NMR Spectra were recorded for solutions in deuteriochloroform with tetramethylsilane as an internal standard unless otherwise stated.…”
Section: Methodsmentioning
confidence: 99%
“…1 H NMR (300 MHz) and 13 C NMR (75.4 MHz) spectra were recorded on a Varian Unity 300 apparatus with deuteriochloroform as internal standard. Mass spectra (EI, ionising voltage 70 eV) were determined using a Hewlett-Packard Model 5988A mass-selective detector equipped with a Hewlett-Packard MS Chem Station.…”
Section: Methodsmentioning
confidence: 99%
“…spectra were obtained, as dispersions in KBr, on a Perkin-Elmer Model 583 spectrometer. 1 H NMR (300 MHz) and 13 C NMR (75.4 MHz) spectra were recorded on a Varian Unity 300 apparatus with deuteriochloroform as internal standard. Chemical shifts are given in ppm.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations