2000
DOI: 10.1016/s0043-1648(99)00334-8
|View full text |Cite
|
Sign up to set email alerts
|

The effect of relative humidity on friction and pull-off forces measured on submicron-size asperity arrays

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

7
53
0

Year Published

2005
2005
2019
2019

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 106 publications
(60 citation statements)
references
References 15 publications
7
53
0
Order By: Relevance
“…Then indeed a distribution with two peaks was observed (Fig.4.15), one with low adhesion forces caused by interaction with the silicon wafer, another at higher forces caused by the interaction with TiO 2 . This results agree with results of Ando on roughness surface [183]. The mean value of adhesion force between silicon tip and TiO 2 was two times the adhesion force between silicon tip and silicon wafer.…”
Section: Resultssupporting
confidence: 92%
See 1 more Smart Citation
“…Then indeed a distribution with two peaks was observed (Fig.4.15), one with low adhesion forces caused by interaction with the silicon wafer, another at higher forces caused by the interaction with TiO 2 . This results agree with results of Ando on roughness surface [183]. The mean value of adhesion force between silicon tip and TiO 2 was two times the adhesion force between silicon tip and silicon wafer.…”
Section: Resultssupporting
confidence: 92%
“…This is with AFM [69,119,[190][191][192][193][194][195][196][197][198]. Many experiments showed a significant dependency of the adhesion force on the relative humidity [40,52,54,56,57,183]. A continuous increase humidity was, for example, observed for the interaction of a silicon nitride tip with mica [194], between silica particles [199], a silica particle and a silicon wafer [200], or between a silicon nitride tip and molybdenum trioxide [201].…”
Section: Influence Of Humidity On Adhesionmentioning
confidence: 91%
“…They observed good agreement with this model when looking at the increase in angle of repose of model substances with time and humidity. An analogous experiment on the nanoscale was done by Ando [690]. They used microfabricated silicon arrays of asperities and AFM silicon probes with a flat of 0.7 mm  0.7 mm at the end.…”
Section: Meniscus Forcementioning
confidence: 99%
“…Literature indicates that at 20°C and 35%RH, when the load is varied between 20 nN and 250 nN, there is no significant change in the adhesion force [9].…”
Section: Atomic Force Microscopymentioning
confidence: 99%