2006
DOI: 10.1016/j.bios.2005.04.008
|View full text |Cite
|
Sign up to set email alerts
|

The biosensor based on the pyruvate oxidase modified conducting polymer for phosphate ions determinations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

4
36
0

Year Published

2007
2007
2020
2020

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 123 publications
(40 citation statements)
references
References 32 publications
4
36
0
Order By: Relevance
“…Electrochemical techniques; like voltammetry based on thin film self-assembled monolayers (SAMs) (Reynes et al, 2008;Aoki et al, 2003), stripping analysis (Lundquist and Cox, 1974), enzyme modified electrode biosensors (Rahman et al, 2006;Mak et al, 2003) and potentiometry based on ion-selective electrodes (Kim et al, 2008), usually enjoy the simplicity, lower price, and better analytical characteristics (Bersier et al, 1994). Besides, the instrumentation is lightweight, compact, easily be taken into the field, and readily be automated (Howell et al, 2003).…”
Section: Introductionmentioning
confidence: 99%
“…Electrochemical techniques; like voltammetry based on thin film self-assembled monolayers (SAMs) (Reynes et al, 2008;Aoki et al, 2003), stripping analysis (Lundquist and Cox, 1974), enzyme modified electrode biosensors (Rahman et al, 2006;Mak et al, 2003) and potentiometry based on ion-selective electrodes (Kim et al, 2008), usually enjoy the simplicity, lower price, and better analytical characteristics (Bersier et al, 1994). Besides, the instrumentation is lightweight, compact, easily be taken into the field, and readily be automated (Howell et al, 2003).…”
Section: Introductionmentioning
confidence: 99%
“…However, to avoid any interference from materials such as ascorbic acid, uric acid, acetaminophenone etc., a preoxidizing cell was incorporated in the system for the oxidation of these species. For same samples, a lower detection limit and response time of 0.3 lM and 6 s, respectively, has been reported for the biosensor fabricated by covalent immobilization of POD onto nanoparticle composed conducting polymers (Rahman et al 2006), with good anti-interference ability to the species mentioned earlier. The advantage of incorporating nanoparticles composed conducting polymers was that it exhibits a high surface area and thus, favors a high enzyme loading.…”
Section: Mono-enzymatic Biosensorsmentioning
confidence: 93%
“…In this method, inorganic phosphate reacts with ammonium molybdate to produce phospho-molybdate (reduced), which is measured at 340 nm. However, this method is tedious and time consuming (Kwan et al 2005;Rahman et al 2006). Moreover, use of some carcinogenic chemicals, such as molybdenum, makes this procedure, health hazardous (Zhang et al 2008;Gilbert et al 2011).…”
Section: Conventional Methods Of Phosphate Detectionmentioning
confidence: 98%
See 2 more Smart Citations