2016
DOI: 10.1118/1.4961744
|View full text |Cite
|
Sign up to set email alerts
|

Technical Note: Multicenter study of TrueBeam FFF beams with a new stereotactic diode: Can a common small field signal ratio curve be defined?

Abstract: EFS measurements were confirmed to be mandatory when comparing SRs over different centers. An equation establishing a functional relation between SRs and the EFS was obtained and tested for the new Razor diode.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
10
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 15 publications
(10 citation statements)
references
References 44 publications
(43 reference statements)
0
10
0
Order By: Relevance
“…This exploratory phase resulted in better defined guidelines on how to design our subsequent studies. A multicentric [6] study on small-field dosimetry was then performed using the 10 FFF MV beam on 8 True-Beam linacs, with the awareness that EFS measurements were mandatory when comparing OF data over different centers. A strong relationship between OF det and the EFS was obtained and its suitability in evaluating uncorrect OF was assessed indicating the Razor as a good detector for small-beam OF evaluation.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…This exploratory phase resulted in better defined guidelines on how to design our subsequent studies. A multicentric [6] study on small-field dosimetry was then performed using the 10 FFF MV beam on 8 True-Beam linacs, with the awareness that EFS measurements were mandatory when comparing OF data over different centers. A strong relationship between OF det and the EFS was obtained and its suitability in evaluating uncorrect OF was assessed indicating the Razor as a good detector for small-beam OF evaluation.…”
Section: Discussionmentioning
confidence: 99%
“…This may lead to a possible increase of those dosimetric uncertainties that represent the major features of small beams in comparison to wide fields [1][2][3]. Sharing of the measured data in terms of output factors (OF) for small fields, with regard to many different combinations of machines and dosimeters [4][5][6][7][8], was promoted with a specific working group focused on SBRT. Other had similar experiences [9,10], all with the aim to quantify systematic inaccuracies of small fields dosimetry.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…In detail, 15 full papers. [19][20][21][22][23][28][29][30][31][32][34][35][36]38,40 5 reviews, 18,27,33,37,41 1 editorial, 25 and 3 letters to the editor 24,26,39 were published. A total of more than 100 medical physicists were authors of at least one article, showing high level of members' engagement.…”
Section: B Engagement Metricsmentioning
confidence: 99%