SBRT represents a feasible alternative for the treatment of colorectal liver metastases not amenable to surgery or other ablative treatments in selected patients, showing optimal LC and promising survival rate.
Stereotactic body radiation therapy is a safe and effective therapeutic option for HCC lesions unsuitable to standard loco-regional therapies, with acceptable local control rates and low treatment-related toxicity. The significant correlation between LC and higher doses and between LC and OS supports the clinical value of SBRT in these patients.
BackgroundTo evaluate the feasibility and early side effects of a short course hypo-fractionated SBRT programme with Volumetric Modulated Arc Therapy (VMAT) and Flattening Filter Free (FFF) beams.MethodsA prospective phase I-II study, started on February 2012. Inclusion criteria were: age ≤ 80 years, WHO-PS ≤ 2, PSA ≤ 20 ng/ml, histologically proven prostate adenocarcinoma, T1-T2 stage, no distant metastases, no previous surgery other than TURP, no malignant tumours in the previous 5 years, IPSS 0–7. The schedule was 35 Gy in 5 alternative days. SBRT was delivered with RapidArc VMAT, with 10MV FFF photons. Toxicity assessment was performed according to CTCAE v4.0 scale. EPIC questionnaires assessed Quality-of-Life. Neo-adjuvant/concomitant hormonal-therapy was prescribed according to risk classification. SpaceOAR™ gel was optionally implanted to increase the separation space between the prostate and the rectal wall.ResultsMedian follow-up was 11 months (range: 5–16); 40 patients were recruited in the protocol and treated. According to NCCN criteria, 26/40 patients were low-risk and 14/40 were intermediate risk. Median age was 70 years (56–80), median initial PSA was 6.25 ng/ml (0.50-13.43 ng/ml). Median Gleason score was 6 (6–7). All patients completed the treatment as programmed (median 11.8 days (9–22). Acute Toxicities were as follow: Rectum G0: 30/40 cases (75%); G1: 6/40 (15%); G2: 4/40 (10%). Genito-urinary: G0: 16/40 (40%); G1: 8/40 (20%); G2: 16/34 (40%). In two G2 urinary retention cases, intermittent catheter was needed. No acute G3 or greater toxicity was found. Median treatment time was 126 sec (120–136). SpaceOAR™ was implanted in 8 patients. PSA reduction from the pre-treatment value of the marker was documented in all patients.ConclusionsEarly findings suggest that SBRT with RapidArc and FFF beams for prostate cancer in 5 fractions is feasible and tolerated in acute setting. Longer follow-up is needed for assessment of late toxicity and outcome.
BackgroundTo evaluate a knowledge based planning model for RapidPlan (RP) generated for advanced head and neck cancer (HNC) patient treatments, as well its ability to possibly improve the clinical plan quality. The stability of the model was assessed also for a different beam geometry, different dose fractionation and different management of bilateral structures (parotids).MethodsDosimetric and geometric data from plans of 83 patients presenting HNC were selected for the model training. All the plans used volumetric modulated arc therapy (VMAT, RapidArc) to treat two targets at dose levels of 69.96 and 54.45 Gy in 33 fractions with simultaneous integrated boost. Two models were generated, the first separating the ipsi- and contra-lateral parotids, while the second associating the two parotids to a single structure for training. The optimization objectives were adjusted to the final model to better translate the institutional planning and dosimetric strategies and trade-offs. The models were validated on 20 HNC patients, comparing the RP generated plans and the clinical plans. RP generated plans were also compared between the clinical beam arrangement and a simpler geometry, as well as for a different fractionation scheme.ResultsRP improved significantly the clinical plan quality, with a reduction of 2 Gy, 5 Gy, and 10 Gy of the mean parotid, oral cavity and laryngeal doses, respectively. A simpler beam geometry was deteriorating the plan quality, but in a small amount, keeping a significant improvement relative to the clinical plan. The two models, with one or two parotid structures, showed very similar results. NTCP evaluations indicated the possibility of improving (NTCP decreasing of about 7%) the toxicity profile when using the RP solution.ConclusionsThe HNC RP model showed improved plan quality and planning stability for beam geometry and fractionation. An adequate choice of the objectives in the model is necessary for the trade-offs strategies.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.