IECON 2007 - 33rd Annual Conference of the IEEE Industrial Electronics Society 2007
DOI: 10.1109/iecon.2007.4459918
|View full text |Cite
|
Sign up to set email alerts
|

Synthesis of Multilevel Converters Based on Single-and/or Three-phase Converter Building Blocks

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

2
21
0

Year Published

2010
2010
2017
2017

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 21 publications
(23 citation statements)
references
References 22 publications
2
21
0
Order By: Relevance
“…This structure is capable of reaching medium output voltage levels using only standard low voltage mature technology components, as well as minimizing total harmonic distortion THD, which can provide significant reduction of output passive filters. This kind of converters also features a high modularity degree because each converter can be seen as a module with similar circuit topology, control structure and modulation [16,34,44]. Thus, in case of a fault in one of these modules, it is possible to replace it quickly and easily.…”
Section: Cmc In Recent Research and Applicationsmentioning
confidence: 99%
“…This structure is capable of reaching medium output voltage levels using only standard low voltage mature technology components, as well as minimizing total harmonic distortion THD, which can provide significant reduction of output passive filters. This kind of converters also features a high modularity degree because each converter can be seen as a module with similar circuit topology, control structure and modulation [16,34,44]. Thus, in case of a fault in one of these modules, it is possible to replace it quickly and easily.…”
Section: Cmc In Recent Research and Applicationsmentioning
confidence: 99%
“…The other advantage for the cascaded multilevel inverter is its modular structure. This topology is constructed from smaller units with the same structure and control circuit [10]. When an error occurs in one of the units, this feature makes it possible for the defective unit to be easily and quickly replaced with a fault-free unit.…”
Section: Introductionmentioning
confidence: 99%
“…Generally, a single-phase inverter requires an extra full-bridge circuit known as a folded cascaded or polarity generation circuit [15], [16]. The final output voltage is synthesized by the combination of the input DC voltages of all series-connected units [11], [17]. This topology exhibits modular characteristics because all its units are similar and share the same control strategy.…”
Section: Introductionmentioning
confidence: 99%