“…The least square treatment of calibration data yielded the regression equation A = 0.0019 + 1.3979C with a correlation coefficient of 0.9999, indicating the excellent linearity of the calibration curve. The 95% confidence limits 21 for slopes and intercepts of the regression lines pointed towards a high reproducibility of the proposed method. In order to verify that the developed method is free from procedural errors, the experimental intercept, a, of the regression line was tested for significance of the deviation from the expected value zero.…”
Section: Development and Validation Of Analytical Methods Calibration mentioning
confidence: 94%
“…The least square treatment of calibration data yielded the regression equation A = 0.0019 + 1.3979C with a correlation coefficient of 0.9999, indicating the excellent linearity of the calibration curve. The 95% confidence limits 21 for slopes and intercepts of the regression lines pointed towards a high reproducibility of the proposed method. In order to verify that the developed method is free from procedural errors, the experimental intercept, a, of the regression line was tested for significance of the deviation from the expected value zero.…”
Section: Development and Validation Of Analytical Methods Calibration mentioning
confidence: 94%
“…Data processing was performed by Excalibur 1.4 software. Samples for HPLC-MS/MS were prepared and analyzed by using the procedure described for the quantitative determination [2][3][4][5].…”
Section: Methodsmentioning
confidence: 99%
“…Their wide pharmaceutical application causes an ever-growing interest for fast, simple and reliable analytical methods for analytical determinations in binary mixtures. Cephalosporins liquid binary mixtures have already been studied by Morelly [2][3][4][5] by using first-and second-derivative spectrophotometry. Binary mixtures of cephalothin and clavulanic acid were analyzed by means of first derivative spectrophotometry [6].…”
Section: Introductionmentioning
confidence: 99%
“…Regression analysis of the calibration data also make it possible to evaluate the error, S c , in the determination of a given concentration of verapamil hydrochloride [39]. Figure 6 shows the graph of S c against the concentration of verapamil hydrochloride.…”