2008
DOI: 10.1016/j.jpba.2008.04.026
|View full text |Cite
|
Sign up to set email alerts
|

Determination of cephalosporins in solid binary mixtures by polarized IR- and Raman spectroscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
5
0

Year Published

2009
2009
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 22 publications
(6 citation statements)
references
References 16 publications
0
5
0
Order By: Relevance
“…Figure 5a demonstrates the most informative Raman spectral features for cefixime are 398 cm À1 (stretching of titanium powder), 515 cm À1 (stretching vibrations of Ti), 638 cm À1 (Ti bend [anatase]), [32] 737 cm À1 (C-N-C scissoring of the lactam ring and CH wagging), [33] 1090 cm À1 (C-N stretching), [34] 1303 cm À1 (CH 2 wagging), 1339 cm À1 (C-O stretching), [35] and 1614 cm À1 (C=O stretching of amide-I). [33,36] The feature having highest VIP of 6 is 1614 cm À1 and contributing most in providing information for training PLSR model.…”
Section: Development Of the Plsr Modelmentioning
confidence: 99%
“…Figure 5a demonstrates the most informative Raman spectral features for cefixime are 398 cm À1 (stretching of titanium powder), 515 cm À1 (stretching vibrations of Ti), 638 cm À1 (Ti bend [anatase]), [32] 737 cm À1 (C-N-C scissoring of the lactam ring and CH wagging), [33] 1090 cm À1 (C-N stretching), [34] 1303 cm À1 (CH 2 wagging), 1339 cm À1 (C-O stretching), [35] and 1614 cm À1 (C=O stretching of amide-I). [33,36] The feature having highest VIP of 6 is 1614 cm À1 and contributing most in providing information for training PLSR model.…”
Section: Development Of the Plsr Modelmentioning
confidence: 99%
“…Laboratory‐based Raman instruments have been widely used for quantification of APIs in different pharmaceutical matrices . Because the Raman signal is proportional to concentration, the use of univariate regression was an option.…”
Section: Introductionmentioning
confidence: 99%
“…Both drugs were quantified with an accuracy of 3.35 and 3.46%, respectively. Another class of antibiotics, cephalosporins, were quantified using Raman spectroscopy and univariate regression by taking the peak ratio of the absorption bands at 800 and 721 cm –1 . On the other hand, when there was a lot of variation in the data resulting from the complexity of the tablets analysed, the Raman scattering of the tablet was not limited to the API of interest only .…”
Section: Introductionmentioning
confidence: 99%
“…Determination of cephalosporins in solid binary mixtures has been conducted via infrared and Raman spectroscopy [3] . Cephalosporins in liquid binary mixtures, such as cephapirin and cefuroxime, have been assayed using first and second spectrophotometric methods [4,5] .…”
mentioning
confidence: 99%
“…The C=C stretching of the cyclopentadiene ring is presented at 1 500 cm −1 , and the peak at 1 587 cm −1 is the C=C stretching of thiazine ring. The peak at 1 641 cm −1 in the CTX spectrum, as well as the peak at 1 627 cm −1 in the COL and CRO spectra, can be assigned to the C=O stretching vibrations of amide groups [3,12,13] .…”
mentioning
confidence: 99%