2010
DOI: 10.1016/j.snb.2010.05.045
|View full text |Cite
|
Sign up to set email alerts
|

Software-based quantitation of bioassays on CD

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
9
0
1

Year Published

2012
2012
2016
2016

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 8 publications
(11 citation statements)
references
References 8 publications
1
9
0
1
Order By: Relevance
“…157,159 3.4.2 Gold NPs. The abovementioned readout strategies for CD/DVD drive assays have been used to monitor streptavidinbiotin binding, 160 for DNA hybridization assays 156 and immunoassays, 157,161 and for assaying metal ions. 162 Recently, BRD optical drives have also been used for readout of biotin-streptavidin interactions, 163 competitive immunoassays and DNA hybridization assays.…”
Section: Technologymentioning
confidence: 99%
“…157,159 3.4.2 Gold NPs. The abovementioned readout strategies for CD/DVD drive assays have been used to monitor streptavidinbiotin binding, 160 for DNA hybridization assays 156 and immunoassays, 157,161 and for assaying metal ions. 162 Recently, BRD optical drives have also been used for readout of biotin-streptavidin interactions, 163 competitive immunoassays and DNA hybridization assays.…”
Section: Technologymentioning
confidence: 99%
“…Typically, CDs are prepared by activating the polycarbonate surface with UV/ozone treatment followed by the use of a PDMS stamp to apply surface patterning. 2,9,27 Following CD disc preparation, samples are applied and allowed to incubate for extended periods of time. Once assays are complete, the disc is loaded into a CD-drive where the extent and location of errors in disc reading directly detect and quantify compounds of interest.…”
Section: Point-of-care Assaysmentioning
confidence: 99%
“…A similar example of a reading error detection-based disc assay is demonstrated by Pallapa et al in the development of a quantitative biotin-streptavidin binding assay utilizing Iso-Buster soware for the more specic detection of erroneous bits in a frame as opposed to total error number alone. 27 Identifying where errors took place on disc allows the most direct approach for the modication of a CD to biomedical diagnostics and allows various data formats to be used. Using the IsoBuster analysis soware, the results depict a clear dependence of reading error on streptavidin concentration.…”
Section: Point-of-care Assaysmentioning
confidence: 99%
See 1 more Smart Citation
“…En lo que se refiere al policarbonato, La Clair et al 83 141 , han llevado a cabo la inmovilización covalente de sondas de ácidos nucleicos y proteínas sobre discos compactos previamente activados con grupos carboxílicos, mediante irradiación UV (254-300 nm) en una atmósfera rica en ozono.…”
Section: Funcionalización De Superficies Poliméricasunclassified