2019
DOI: 10.1016/j.materresbull.2018.11.016
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous detection of 2, 4-dichlorophenoxyacetic acid and fenitrothion through lanthanide doped β-NaYF4 upconversion nanoparticles with different emitting light colors

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 18 publications
(7 citation statements)
references
References 36 publications
0
7
0
Order By: Relevance
“…Yu et al. [ 158 ] reported an LFA based on UCNPs that emitted differently colored light for the simultaneous detection of 2,4‐D and fenitrothion, with LODs of 5 and 12 ng mL −1 , respectively.…”
Section: Applicationsmentioning
confidence: 99%
“…Yu et al. [ 158 ] reported an LFA based on UCNPs that emitted differently colored light for the simultaneous detection of 2,4‐D and fenitrothion, with LODs of 5 and 12 ng mL −1 , respectively.…”
Section: Applicationsmentioning
confidence: 99%
“…1,18 The Eu element can effectively reduce the background interference of traditional labelling materials (such as uorescent dyes, enzymes, and gold nanoparticles). [19][20][21] Europium oxide latex microspheres prepared with the Eu element can emit orange-red uorescence under UV-light of 365 nm. 22 Most TRFIA strips oen use europium oxide latex microsphere as marking materials, 23 and specic biological materials (such as antibodies and aptamers) as core recognition elements, which are coupled to form detection probes.…”
Section: Introductionmentioning
confidence: 99%
“…15,20,25, 30, 35, 40, and 45 mg) when coupling Eu-SaMIgGs, and compared the color development of different Cline positions. As can be seen from Fig.4A, when the SaMIgG dose was 35 mg, the color development degree of the C-line reached the maximum, and the color development degree remained unchanged even aer increasing the dose.…”
mentioning
confidence: 99%
“…Previous studies have reported that researchers constructed immunochromatographic test strips for the detection of 2,4-D based on traditional antibodies and up conversion nanoparticles (UCNPs) materials, with a detection limit of 5 ng/mL [ 28 , 29 ]. However, in the reported papers, traditional antibodies have certain limitations in terms of stability, so their practical application effect will be limited.…”
Section: Resultsmentioning
confidence: 99%