2012
DOI: 10.4012/dmj.2012-013
|View full text |Cite
|
Sign up to set email alerts
|

Shear and micro-shear bond strengths of four self-etching adhesives measured immediately and 24 hours after application

Abstract: This study measured the immediate and 24 h shear (SBS) and micro-shear bond strengths (MSBS) to dentin of four self-etching adhesives. A resin composite was bonded using each adhesive to the area of 5-mm diameter for SBS test or 0.75-mm diameter for MSBS test of flat bovine dentin. The bond strengths of all adhesives at 10 min were lower than at 24 h for both tests. The mean SBS (MPa, 10 min, 24 h) were similar in ranking order at both time periods that is:

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
14
0
2

Year Published

2015
2015
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 18 publications
(18 citation statements)
references
References 26 publications
0
14
0
2
Order By: Relevance
“…In this and previous studies, the all-in-one self-etch system achieves acceptable dentin bond strength [32,33], but the durability of the all-in-one self-etch system remains a matter of concern.…”
Section: Discussionmentioning
confidence: 99%
“…In this and previous studies, the all-in-one self-etch system achieves acceptable dentin bond strength [32,33], but the durability of the all-in-one self-etch system remains a matter of concern.…”
Section: Discussionmentioning
confidence: 99%
“…Moreover, micro-bond tests are used to evaluate adhesives at small areas. (36) Storage of specimens in water has been used invitro to age adhesives, in addition to aging thermo-cycling is commonly used to simulate thermal changes that occur in the oral environment. (37) Most of the invitro bond strength tests are performed after 24 hours of water storage of the specimens.…”
Section: Discussionmentioning
confidence: 99%
“…In the oral environment the interface is subjected to different kinds of stresses immediately after placement. (36) Thermocycling was done in an attempt to assess the ability of EGCG to maintain collagen stabilization under fluctuating temperatures. This protocol was done according to the ISO.…”
Section: Discussionmentioning
confidence: 99%
“…13 Diğer bir taraftan, bazı çalışmalarda da bağ-lanma dayanımı testlerinde iki aşamalı self-etch adeziv sistemlerin tek aşamalı self-etch adeziv sistemlere göre daha yüksek değerler verdiği gösterilmiştir. 9,11 Harnirattisai ve ark., iki aşamalı sistemlerde ikinci aşamada uygulanan çözücü içermeyen hidrofobik bonding rezinler ile daha hidrofilik ve daha fazla su absorbe edebilen tek aşamalıların oluşturduğundan daha kuvvetli bir bağlantı ara yüz tabakası oluşturabileceğini belirtmişlerdir. 11 Bizim çalışmamızın sonuçları ise yukarıdaki çalışmalar ile uyumludur.…”
Section: Discussionunclassified
“…9,11 Harnirattisai ve ark., iki aşamalı sistemlerde ikinci aşamada uygulanan çözücü içermeyen hidrofobik bonding rezinler ile daha hidrofilik ve daha fazla su absorbe edebilen tek aşamalıların oluşturduğundan daha kuvvetli bir bağlantı ara yüz tabakası oluşturabileceğini belirtmişlerdir. 11 Bizim çalışmamızın sonuçları ise yukarıdaki çalışmalar ile uyumludur. Klinikte kullanılan materyallerin biyouyumluluğu son derece önemli bir kriterdir.…”
Section: Discussionunclassified