2016
DOI: 10.1016/j.epsr.2016.03.008
|View full text |Cite
|
Sign up to set email alerts
|

Setup and performances of the real-time simulation platform connected to the INELFE control system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
15
0
1

Year Published

2018
2018
2024
2024

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 23 publications
(17 citation statements)
references
References 8 publications
0
15
0
1
Order By: Relevance
“…INELFE project (France‐Spain Electrical Interconnection) is introduced in Dennetire et al in terms of control stage using hardware in the loop (HIL) real time simulation platform for BTB MMC‐based HVDC grid. Effectiveness of developed solution is verified by HIL platform.…”
Section: Application Areasmentioning
confidence: 99%
“…INELFE project (France‐Spain Electrical Interconnection) is introduced in Dennetire et al in terms of control stage using hardware in the loop (HIL) real time simulation platform for BTB MMC‐based HVDC grid. Effectiveness of developed solution is verified by HIL platform.…”
Section: Application Areasmentioning
confidence: 99%
“…Advances in ICT are playing a key role in the development of real-time simulation technologies. With the incorporation of standards and protocols of communication, data management, and control, such as IEC 61850 [17,19,36,49,51,69,70], IEC 61970 [69,71], and DNP3 [17,38,47,49,60,72,73], applications that previously needed equipment and devices to be close to each other due to connectivity and data acquisition requirements are no longer subject to this limitation. Using Ethernet and WLAN networks through the protocols as mentioned, it is possible to integrate, simulate, and monitor in real time the performance and behavior of protection, control, and communications equipment and devices that comprise the real electrical grid.…”
Section: Fig 4 Phil Schemementioning
confidence: 99%
“…Using Ethernet and WLAN networks through the protocols as mentioned, it is possible to integrate, simulate, and monitor in real time the performance and behavior of protection, control, and communications equipment and devices that comprise the real electrical grid. In this way, it is possible to obtain a precise reproduction of the system and to test it over different operating conditions established by engineers and all from centralized or unified workstations, called "WAMPAC" [36,37,40,41,49,69] or "CPCS" [70,[74][75][76].…”
Section: Fig 4 Phil Schemementioning
confidence: 99%
See 1 more Smart Citation
“…To guarantee the reliability and accuracy of STATCOMs' performance, evaluating STATCOM's performance against vendor's validated model after commissioning or controller update is mandatory [6] [7]. However, the complexity of STATCOM control system and different control modes present challenges for operator and field engineers to verify devices' behavior.…”
Section: Introductionmentioning