1998
DOI: 10.1016/s0379-0738(98)00023-1
|View full text |Cite
|
Sign up to set email alerts
|

Separation of some black rollerball pen inks by capillary electrophoresis: preliminary data

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
18
0

Year Published

1999
1999
2014
2014

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 38 publications
(18 citation statements)
references
References 10 publications
0
18
0
Order By: Relevance
“…Other techniques include capillary electrophoresis (CE) [10,32], inductively coupled plasma mass spectrometry (ICP-MS) [33,34], laser ablation ICP-MS [35], field desorption mass spectrometry (FD-MS) [14] and ion-electrospray ionization mass spectrometry (ESI-MS) [4]. FD-MS, ESI-MS, ICP-MS, and to a slightly lesser extent LA-ICP-MS, remain semi-destructive techniques as they require the dissolution or removal of the ink from the paper in order to perform the analysis.…”
Section: Document Analysismentioning
confidence: 99%
“…Other techniques include capillary electrophoresis (CE) [10,32], inductively coupled plasma mass spectrometry (ICP-MS) [33,34], laser ablation ICP-MS [35], field desorption mass spectrometry (FD-MS) [14] and ion-electrospray ionization mass spectrometry (ESI-MS) [4]. FD-MS, ESI-MS, ICP-MS, and to a slightly lesser extent LA-ICP-MS, remain semi-destructive techniques as they require the dissolution or removal of the ink from the paper in order to perform the analysis.…”
Section: Document Analysismentioning
confidence: 99%
“…In contrast to this, MEKC allows for distinction between inks. Zlotnick and Smith [21] have been reported on the preliminary analysis of some black rollerball pen inks using the MEKC method, in which an SDS containing borate buffer was used. Based on this, however, we found that the use of a phosphate solution also provided satisfying separation efficiency.…”
Section: Comparison Of a Blue Ink Analysis By Cze And Mekcmentioning
confidence: 99%
“…Fluorescence detection helped to improve the discriminating power of the method, as several inks containing the same UV response gave different fluorescence profiles. Zlotnick and Smith [52] have utilized MEKC with borate SDS buffers in the analysis of rollerball inks. The results demonstrated the potential of CE to analyze such samples and noted the advantage that small sample sizes can be used in this technique.…”
Section: Explosives Residue Gunshot Residue Ink and Dye Analysismentioning
confidence: 99%