2015
DOI: 10.1021/jf5052128
|View full text |Cite
|
Sign up to set email alerts
|

Rapid and Sensitive Detection of the Food Allergen Glycinin in Powdered Milk Using a Lateral Flow Colloidal Gold Immunoassay Strip Test

Abstract: A rapid immunochromatographic lateral flow test strip in a sandwich format was developed with the colloidal gold-labeled mouse antiglycinin monoclonal antibody (mAb) and rabbit antiglycinin polyclonal antibody (pAb) to specifically identify glycinin, a soybean allergen. The test strip is composed of a sample pad, a conjugate reagent pad, an absorbent pad, and a test membrane containing a control line and a test line. This test strip has high sensitivity, and results can be obtained within 10 min without sophis… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
26
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
3
3
2

Relationship

0
8

Authors

Journals

citations
Cited by 68 publications
(26 citation statements)
references
References 30 publications
(47 reference statements)
0
26
0
Order By: Relevance
“…It is therefore useful to determine immunoassay sensitivity, specificity, and robustness for optimal assay performance. Until recently, dipstick (lateral flow device) immunoassays have been used for qualitative applications (Poms et al 2004, van Hengel 2007, and efforts have been reported to develop their quantitative counterparts (Zheng et al 2012, Wang et al 2015. Simple and rapid dipstick formats offer portability and operational ease.…”
Section: Miscellaneous Methodsmentioning
confidence: 99%
“…It is therefore useful to determine immunoassay sensitivity, specificity, and robustness for optimal assay performance. Until recently, dipstick (lateral flow device) immunoassays have been used for qualitative applications (Poms et al 2004, van Hengel 2007, and efforts have been reported to develop their quantitative counterparts (Zheng et al 2012, Wang et al 2015. Simple and rapid dipstick formats offer portability and operational ease.…”
Section: Miscellaneous Methodsmentioning
confidence: 99%
“…IC 50 of the the mAb against CLOP was 0.275 ng/mL, LOD was 0.018 ng/mL, and the linear range of detection was from 0.032 ng/mL to 0.896 ng/mL. studies (Wang et al, 2020;Wang et al, 2015) have proven that the antibodies and pH are essential to the function of GNP-labeled anti-CLOP mAb conjugates. Thus, in this study, GNP solutions were tested at different pH values (4.5, 5.5, 6.5, 7.5, and 8.5).…”
Section: Optimization Of a Gnp-based Lateral-flow Colloidal Gold Immumentioning
confidence: 96%
“…Other chromatographic sandwich immunoassays have been described for IL-5, anti-HCV antibodies, potato virus X, cardiac troponin and myoglobin [81][82][83][84]. Sandwich immunoassays have also been applied to the determination of allergens, bacteria and toxins in food [85][86][87][88][89].…”
Section: Sandwich Immunoassaysmentioning
confidence: 99%
“…For example, the use of nanomaterials, such as gold or silver nanoparticles, and quantum dots should continue to lead to new or enhanced detection methods and formats for these methods [19,[85][86][87][88][93][94][95][96][97][98][99][100]109]. The utilization of alternative supports, such as affinity monoliths, is also expected to continue [110][111][112][113][114][115][116].…”
Section: Future Perspectivementioning
confidence: 99%
See 1 more Smart Citation