2008
DOI: 10.1365/s10337-008-0777-1
|View full text |Cite
|
Sign up to set email alerts
|

Quantitative Determination of Microcystins in Rat Plasma by LC–ESI Tandem MS

Abstract: A rapid and sensitive method was developed and validated for the determination of MCYST (microcystin)-RR, -LR, and [Dha 7 ] MCYST-LR in rat plasma by liquid chromatography-tandem mass spectrometry. The analytes were extracted from rat plasma by protein precipitation, followed by solid-phase extraction. Liquid chromatography with electrospray ionization mass spectrometry, operating in selected reaction monitoring (SRM) mode, was used to quantify MCYST-RR, -LR, and [Dha 7 ] MCYST-LR in rat plasma. The … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

3
6
0

Year Published

2009
2009
2019
2019

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 8 publications
(9 citation statements)
references
References 32 publications
3
6
0
Order By: Relevance
“…We obtained LOD values ranging between 1 fg/μL (MC LW, MC LF) and 9 fg/μL (MC YR). The literature reports LODs ranging between pg/μL and ng/μL . Our observed instrumental detection limits are similar to the best LOD values reported in the literature using ESI(+)‐MS/MS, proving that our method is a valid alternative.…”
Section: Resultssupporting
confidence: 86%
See 3 more Smart Citations
“…We obtained LOD values ranging between 1 fg/μL (MC LW, MC LF) and 9 fg/μL (MC YR). The literature reports LODs ranging between pg/μL and ng/μL . Our observed instrumental detection limits are similar to the best LOD values reported in the literature using ESI(+)‐MS/MS, proving that our method is a valid alternative.…”
Section: Resultssupporting
confidence: 86%
“…We developed a chromatographic separation using alkaline conditions, resulting in high‐resolution separation. The LODs for all toxins were determined between 1 and 9 fg/μL, which are similar to or lower than those reported in the iterature, while the MDLs ranged between 23 and 164 pg absolute amount. As no available cyanotoxin certified reference atmospheric materials exist, we validated the method by spiking five clean fibre filters.…”
Section: Discussionsupporting
confidence: 79%
See 2 more Smart Citations
“…most widely used as extraction solvent in biological fluid samples [2,[28][29][30]. In the plasma preparation, methanol was chosen for further development as it had better recoveries (93.7%, 91.1% and 85.8% for MC-RR, MC-RR-GSH and MC-RR-Cys, respectively), which were obviously higher than those of acetonitrile (78.6%, 75.0% and 78.2%) and EDTA-Na 2 (0.01 M)-5% acetic acid (35.6%, 32.9% and 32.8%).…”
Section: Fig 3 Mean Recoveries Of Mc-rr Mc-rr-gsh and Mc-rr-cys Spmentioning