2018
DOI: 10.1007/s00216-018-1031-9
|View full text |Cite
|
Sign up to set email alerts
|

Pipette-tip solid-phase extraction using polypyrrole as efficient adsorbent for extraction of avermectins and milbemycins in milk

Abstract: In this work, we developed a HPLC method for the multidetermination of avermectins (AVM) (abamectin-ABA 1b and ABA 1a, eprinomectin-EPR, and ivermectin-IVM) and milbemycins (moxidectin-MOX) in milk samples using polypyrrole (PPy) as adsorbent material in pipette-tip solid-phase extraction (PT-PPy-SPE). PPy was characterized by scanning electron microscopy, thermogravimetric analysis, Fourier transform infrared spectroscopy, and X-ray diffraction and the data agreed with the literature. The sample preparation i… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0
2

Year Published

2020
2020
2024
2024

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 16 publications
(8 citation statements)
references
References 43 publications
0
6
0
2
Order By: Relevance
“…Besides, HMs showed an absorption band at around 1700 cm −1 referring to the bond CO and CAS showed a band at around 1683 cm −1 due to CN stretching, which confirms the presence of crosslinking between casein and glutaraldehyde and band attributed to the carboxylate group (O–C–O) at 1415 cm −1 . 20–22,27,28…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Besides, HMs showed an absorption band at around 1700 cm −1 referring to the bond CO and CAS showed a band at around 1683 cm −1 due to CN stretching, which confirms the presence of crosslinking between casein and glutaraldehyde and band attributed to the carboxylate group (O–C–O) at 1415 cm −1 . 20–22,27,28…”
Section: Resultsmentioning
confidence: 99%
“…Besides, HMs showed an absorption band at around 1700 cm −1 referring to the bond C]O and CAS showed a band at around 1683 cm −1 due to C]N stretching, which conrms the presence of crosslinking between casein and glutaraldehyde and band attributed to the carboxylate group (O-C-O) at 1415 cm −1 . [20][21][22]27,28 The TGA data evidenced that all materials were thermally stable at room temperature and curves showed two different thermal events for each material (Fig. 2b), but all presented a difference between them.…”
Section: Characterizationmentioning
confidence: 94%
“…In conclusion, the compounds of series A are methoxylated at the 5-position, unlike the B-series with a hydroxyl group not derived from the same 5-position. AVMs are characterized by the presence of a substituent of a glucose molecule at position 13 and a sec-butyl substituent at carbon 25 (Milhome et al, 2009;Danaher et al, 2006;Hernández-Borges et al, 2007;Florez et al, 2018). Because of the lipophilic properties of the AVMs and the long-term permanence of their residues in the animals' bodies, especially in milk, they promote the risk of intoxication for consumers.…”
Section: Introductionmentioning
confidence: 99%
“…Palavras-chave: didática das ciências experimentais, prática laboratorial, preparação de amostras, SPE, HPLC Los procedimientos analíticos requieren técnicas de preparación de muestras como un paso esencial para obtener resultados confiables, lo cual garantiza la reproducibilidad y disminuye la profusión de errores, en pro de una confiabilidad estadística de los datos obtenidos (Alcántara-Durán et al, 2018;Angulo et al, 2018). En esta perspectiva, la microextracción en fase sólida emerge como una alternativa viable, en virtud de la rapidez del análisis, de la reducción de la muestra y de volúmenes de disolventes, de la simplicidad de su empleo, así como de sus posibilidades para su automatización (Liu et al, 2017).…”
Section: Introductionunclassified
“…La extracción en fase solida adaptada en puntera PT-SPE -pipette-tip solid phase extraction-es uno de los métodos más prometedores para la preparación de muestras miniaturizadas de extracción en fase sólida (Angulo et al, 2018;Jiang et al, 2018;Liu et al, 2017;Yang et al, 2017). Se diferencia de la SPE -solid phase extraction-convencional por precisar de una cantidad mínima de material adsorbente y no necesitar ningún dispositivo de extracción adicional, excepto una jeringa comercial.…”
Section: Introductionunclassified