1985
DOI: 10.1016/0022-0248(85)90155-1
|View full text |Cite
|
Sign up to set email alerts
|

Photoluminescence of Cd-rich Hg1−xCdxTe alloys (0.7<x<1)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
9
0
2

Year Published

1988
1988
2010
2010

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 49 publications
(12 citation statements)
references
References 16 publications
1
9
0
2
Order By: Relevance
“…At higher temperatures, the peak energy follows the bandgap evolution. 9 This again confirms the attribution of this peak to the band-to-band transition. The ME peak attributed to a D°-h transition disappears above 40 K, probably because of ionization of the donor.…”
Section: Arsenic-doped Samplesupporting
confidence: 82%
See 2 more Smart Citations
“…At higher temperatures, the peak energy follows the bandgap evolution. 9 This again confirms the attribution of this peak to the band-to-band transition. The ME peak attributed to a D°-h transition disappears above 40 K, probably because of ionization of the donor.…”
Section: Arsenic-doped Samplesupporting
confidence: 82%
“…2c shows that the high-energy peak emitting at 513 meV at 2 K becomes dominant above 45 K, even in the case of the annealed sample, and follows the same behavior as the high-energy peak of sample A (unintentionally doped); i.e., localization into Urbach states is seen below 120 K. For higher temperatures, the peak center energy follows the bandgap variation. 9 Thus, this peak is attributed to the band-to-band transition. However, in the case of the as-grown sample, another emission at higher energy is seen above 40 K. Above this temperature, two peaks with band-to-band spectral shape are needed to fit the PL spectra.…”
Section: Indium-doped Samplementioning
confidence: 97%
See 1 more Smart Citation
“…Combinations of IR-PL data and E,(x, T ) relations were reported, too: In [66] X-ray microprobe investigations were compared with IR-PL data using empirical E,(x, T ) relations. In [72] the authors developed their own empirical relation for the interpretation of the spectral positions in their spectra.…”
Section: Fr-pl In Hg -Cdtementioning
confidence: 99%
“…The spectra show that the band gap of the sample is around 1.1 eV while the absorption onset is at 1 eV. According to Legros and Triboulet [14] the band gap calculated corresponding to this composition of Hg 1 À x Cd x Te is 1.12 eV indicating that the expected composition of MCT is preserved in the samples. The basic PL behavior of MCT nano-and microcrystals is demonstrated in Fig.…”
Section: Resultsmentioning
confidence: 89%