2016
DOI: 10.1016/j.ijhydene.2015.10.094
|View full text |Cite
|
Sign up to set email alerts
|

Pd-based metallic supported membranes: High-temperature stability and fluidized bed reactor testing

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
50
0

Year Published

2016
2016
2020
2020

Publication Types

Select...
4
2
1

Relationship

2
5

Authors

Journals

citations
Cited by 65 publications
(52 citation statements)
references
References 30 publications
2
50
0
Order By: Relevance
“…achieve high H2 fluxes. On the other hand, metallic supported membranes have shown very good stabilities over time with outstanding selectivities [36,37]. However, the permeance values measured are in general 3-4 times lower than ceramic supported membranes, thus longer membranes should be prepared in order to achieve the desired targets of H2 permeation with the corresponding economical penalty for the process.…”
Section: Metal Based Membranes For H2 Productionmentioning
confidence: 99%
“…achieve high H2 fluxes. On the other hand, metallic supported membranes have shown very good stabilities over time with outstanding selectivities [36,37]. However, the permeance values measured are in general 3-4 times lower than ceramic supported membranes, thus longer membranes should be prepared in order to achieve the desired targets of H2 permeation with the corresponding economical penalty for the process.…”
Section: Metal Based Membranes For H2 Productionmentioning
confidence: 99%
“…Pd-based selective layers onto tubular supports were developed by direct simultaneous Pd and Ag electroless plating deposition [51][52][53][54] in a one step process. Pd membranes for the micro-channel supported membranes were developed using a two-step process [55,56] where the defect free Pd-alloy film is first prepared by sputtering deposition onto the extremely smooth surface of a silicon wafer.…”
Section: Membranesmentioning
confidence: 99%
“…Overall, the use of ceramic supports implies that less surface area is needed in order to achieve high H2 fluxes. On the other side, metallic supported membranes have shown very good stabilities over time with outstanding selectivities [52,53]. Nevertheless, the permeance values measured are 3-4 times lower than ceramic supported membranes when membranes are developed by direct electroless plating (ELP) deposition [51,52], thus a longer membrane area should be prepared in order to achieve the desired target of H2 permeation with the corresponding economical penalty for the process.…”
Section: Membranesmentioning
confidence: 99%
See 2 more Smart Citations