1990
DOI: 10.1039/ja9900500125
|View full text |Cite
|
Sign up to set email alerts
|

On-line isotope dilution and sample dilution by flow injection and inductively coupled plasma mass spectrometry

Abstract: A systematic investigation was made to demonstrate the applicability of a flow injection system for on-line isotope dilution and on-line sample dilution, as obtained by merging the sample solution with the spike solution or with the diluent, respectively. The effect of the sample to spike ratio on the precision and accuracy was examined, and the advantages and limitations of the proposed technique are demonstrated.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
12
0

Year Published

1999
1999
2016
2016

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 41 publications
(13 citation statements)
references
References 12 publications
0
12
0
Order By: Relevance
“…FIA techniques have been coupled to flame atomic absorption spectrometry (FAAS) [15][16][17], inductively coupled plasma atomic emission spectrometry (ICP-AES) [18,19], and ICP-MS [18,19] to achieve on-line dilution. Until now, few workers have attempted to apply this approach to ICP-MS multielement analysis.…”
Section: Introductionmentioning
confidence: 99%
“…FIA techniques have been coupled to flame atomic absorption spectrometry (FAAS) [15][16][17], inductively coupled plasma atomic emission spectrometry (ICP-AES) [18,19], and ICP-MS [18,19] to achieve on-line dilution. Until now, few workers have attempted to apply this approach to ICP-MS multielement analysis.…”
Section: Introductionmentioning
confidence: 99%
“…The multiple injection modes produced transient signals in the spiked samples, covering a wide analyte concentration range. 2,3 This application emphasized the effect of nebulizer flow rate, measurement period and dwell times, along transient signals for isotope ratio (IR) measurements. 3 Klinkenberg et al 22 presented in 1993 a simplified flow scheme to perform time controlled injection of discrete volumes of sample or calibration standard into a continuous flowing isotopic enriched solution.…”
Section: Features For Online Addition Of Enriched Isotope Solutionmentioning
confidence: 99%
“…2,3 This application emphasized the effect of nebulizer flow rate, measurement period and dwell times, along transient signals for isotope ratio (IR) measurements. 3 Klinkenberg et al 22 presented in 1993 a simplified flow scheme to perform time controlled injection of discrete volumes of sample or calibration standard into a continuous flowing isotopic enriched solution. By taking into account the corrections for detector dead time and mass discrimination, the spike composition and concentration were adjusted to provide good precision of IR measurements.…”
Section: Features For Online Addition Of Enriched Isotope Solutionmentioning
confidence: 99%
See 2 more Smart Citations