Microwave-Assisted Sample Preparation for Trace Element Analysis 2014
DOI: 10.1016/b978-0-444-59420-4.00005-2
|View full text |Cite
|
Sign up to set email alerts
|

Microwave-Induced Combustion

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0
2

Year Published

2016
2016
2024
2024

Publication Types

Select...
5
2

Relationship

3
4

Authors

Journals

citations
Cited by 12 publications
(7 citation statements)
references
References 66 publications
0
5
0
2
Order By: Relevance
“…In general, methods based on combustion enable complete decomposition of the matrix with low residual carbon content (RCC) in a relatively short time. In addition, to avoid losses of analytes by volatilization, the combustion must be carried out in closed vessels . In this sense, the microwave-induced combustion (MIC) system may be considered as an interesting alternative for preparing samples prior to Br and I determination.…”
Section: Introductionmentioning
confidence: 99%
“…In general, methods based on combustion enable complete decomposition of the matrix with low residual carbon content (RCC) in a relatively short time. In addition, to avoid losses of analytes by volatilization, the combustion must be carried out in closed vessels . In this sense, the microwave-induced combustion (MIC) system may be considered as an interesting alternative for preparing samples prior to Br and I determination.…”
Section: Introductionmentioning
confidence: 99%
“…O método da MIC foi desenvolvido, inicialmente, para a decomposição de amostras sólidas, 19 sendo que outros tipos de amostras necessitam ser adaptadas para um melhor desempenho deste método. Neste sentido, o uso de cápsulas de policarbonato e de invólucros com filmes de PE podem ser uma alternativa para que as amostras possam ser colocadas no suporte.…”
Section: Otimização Da Mic: Preparação Dos Invólucros Para As Amostrasunclassified
“…Para a determinação de metais, há diversos trabalhos na literatura que utilizam HNO 3 como solução absorvedora. 19 Dessa maneira, neste trabalho foram avaliadas três concentrações de HNO 3 (3, 7 e 14,5 mol L -1 ) para a determinação de metais e S, em RAT e em RV. No procedimento da MIC, foram decompostos 500 mg de RAT e de RV com uma etapa de refluxo de 5 min nos ciclos de decomposição.…”
Section: Avaliação Da Solução Absorvedora No Procedimento Da Micunclassified
“…Literature data showed halogen losses through the formation of volatile compounds, such as HX or X 2 (X = halogen), which can be formed during acid digestion, resulting in non‐quantitative recoveries 17 . Thus, when choosing a sample preparation method, the analyst should consider the type of analytes and their concentrations, as well as the nature of the sample, the determination technique, and the precision and accuracy desired 18 …”
Section: Introductionmentioning
confidence: 99%
“…Thus, MIC provides high throughput and low reagent consumption, and allows the use of several types of solution for analyte absorption, including alkaline reagents. It has also been recommended for the determination of non‐metals in organic samples 18, 31 . In addition, the digests obtained by MIC, in general, are compatible with analysis by various determination techniques 18 …”
Section: Introductionmentioning
confidence: 99%