Laser induced fluorescence model of human goiter

Abstract: Laser induced fluorescence (LIF) with wide area surveillance for resected thyroid tissue solid chunks is presented. The characteristic LIF spectra of goiter were established. The state of tissue at each point represents a superposition of normal and pathology states. To our knowledge two co-existing pathological effects were observed optically for the first time. It is demonstrated that the LIF spectral functions and their intensities well-labeled such areas and represent a good tool for medical diagnostics of… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2008
2008
2018
2018

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 8 publications
(8 citation statements)
references
References 11 publications
0
8
0
Order By: Relevance
“…2 presents the LIF spectra of ileum and liver tissues obtained from control According to our model they represent the B-type molecules. It is well known that if an excitation wavelength of 337 nm is used, then collagen display their fluorescence peaks at approximately 390 nm, and NADH at 470 nm (see for example [11] and the references cited there). Hence, it is evident that, in spite of difference in LIF spectra, in the both kinds of tissue dominate the fluorescence of coenzyme NADH with maximum around 470 nm.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…2 presents the LIF spectra of ileum and liver tissues obtained from control According to our model they represent the B-type molecules. It is well known that if an excitation wavelength of 337 nm is used, then collagen display their fluorescence peaks at approximately 390 nm, and NADH at 470 nm (see for example [11] and the references cited there). Hence, it is evident that, in spite of difference in LIF spectra, in the both kinds of tissue dominate the fluorescence of coenzyme NADH with maximum around 470 nm.…”
Section: Resultsmentioning
confidence: 99%
“…About 2000 measurements were made per spot per sample in these experiments. The temperature increment in the scanning mode did not affect the spectral measurements [11].…”
Section: Laser Induced Fluorescence Spectroscopy (Lifs)mentioning
confidence: 98%
See 1 more Smart Citation
“…About 2 × 10 3 measurements were made per spot per sample in these experiments. The temper ature increment in the scanning mode did not affect the spectral measurements [5].…”
Section: Laser-induced Fluorescence Spectroscopy (Lifs)mentioning
confidence: 88%
“…Emission spectra recorded from 300 to 600 nm were displayed on a PC monitor and stored as data files. About 2,000 measurements were made per spot per sample in these experiments [8] [9].…”
Section: The Lif Spectra Were Obtained By the Following Methodsmentioning
confidence: 99%