1975
DOI: 10.1097/00004032-197511000-00014
|View full text |Cite
|
Sign up to set email alerts
|

Improvements in the Use of Ceramic BeO for TLD

Abstract: Several types of commercially available ceramic Be0 are evaluated for thermoluminescence and combined thermolurninescence-exoelectron dosimetry (TLD-TSEE) . The ceramic Thermalox 995 is superior in nearly all respects. Physical and chemical treatments which enhance or reduce sensitivity and stability of TSEE exert often similar influences on the TL. A thin surface region, which is rich in impurities, suppresses spurious emissions of both light and electrons and allows combined TL and TSEE measurements to be ma… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
10
0

Year Published

1977
1977
2024
2024

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 43 publications
(12 citation statements)
references
References 2 publications
(4 reference statements)
0
10
0
Order By: Relevance
“…Other important dosimetric materials are Al2O3:C, CaSO4:Dy, MgB4O7:Dy, MgB4O7:Gd,Li, BeO etc. [41,44,45,46,47,48,49]. However, those based on LiF, and MgB4O7 having the density of ~2.65 g/cm 3 and 2.53 g/cm 3 , respectively are the most tissue equivalent, and therefore they are so commonly used in dosimetry.…”
Section: Introduction To Energy Storage Materialsmentioning
confidence: 99%
“…Other important dosimetric materials are Al2O3:C, CaSO4:Dy, MgB4O7:Dy, MgB4O7:Gd,Li, BeO etc. [41,44,45,46,47,48,49]. However, those based on LiF, and MgB4O7 having the density of ~2.65 g/cm 3 and 2.53 g/cm 3 , respectively are the most tissue equivalent, and therefore they are so commonly used in dosimetry.…”
Section: Introduction To Energy Storage Materialsmentioning
confidence: 99%
“…The optical sensitivity of BeO is well known since its * Corresponding author. application as TL-material (Tochilin et al, 1969;Crase and Gammage, 1975). Regarding OSL, it was firstly investigated by Bulur and Göksu (1998).…”
Section: Introductionmentioning
confidence: 99%
“…Compared with other commercial thermoluminescence dosimetric systems, the main disadvantage of the BeObased materials is the rapid light-stimulated thermoluminescence fading. Under laboratory fluorescent light, rapid fading of 50 % in 30 min for the thermoluminescence peak at 167 ºC has been reported in several types of commercial BeO ceramic dosimeters (Crase & Gammage, 1975). Based on the characteristic light-sensitive thermoluminescence of BeO, Albrecht and Mandeville (Albrecht & Mandeville, 1956) first investigated optically stimulated luminescence of the X-ray irradiated BeO by using visible photons.…”
Section: Beomentioning
confidence: 99%