2007
DOI: 10.1016/j.radmeas.2007.01.052
|View full text |Cite
|
Sign up to set email alerts
|

New aspects of a BeO-based optically stimulated luminescence dosimeter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
32
0
5

Year Published

2008
2008
2024
2024

Publication Types

Select...
5
3

Relationship

1
7

Authors

Journals

citations
Cited by 101 publications
(39 citation statements)
references
References 6 publications
(5 reference statements)
1
32
0
5
Order By: Relevance
“…Reference [2] discusses some early studies on this topic in detail and includes halides (KCl, KBr, NaCl, RbI, CaF 2 , and BaFX with X = Br, Cl, I), sulfates (MgSO 4 and CaSO 4 ), sulfides (AS, with S = Mg, Sr, Ca, and Ba), and oxides (BeO and fused quartz). Except for BeO [7][8][9], these materials have not yet been adopted in dosimetry because they possess one or more undesirable features such as fading, low sensitivity to radiation, high effective atomic number, or even self-dose [10][11][12][13]. But even BeO has disadvantages: it is toxic in the powder form, so it must be used in the single ceramic form [14].…”
Section: Introductionmentioning
confidence: 99%
“…Reference [2] discusses some early studies on this topic in detail and includes halides (KCl, KBr, NaCl, RbI, CaF 2 , and BaFX with X = Br, Cl, I), sulfates (MgSO 4 and CaSO 4 ), sulfides (AS, with S = Mg, Sr, Ca, and Ba), and oxides (BeO and fused quartz). Except for BeO [7][8][9], these materials have not yet been adopted in dosimetry because they possess one or more undesirable features such as fading, low sensitivity to radiation, high effective atomic number, or even self-dose [10][11][12][13]. But even BeO has disadvantages: it is toxic in the powder form, so it must be used in the single ceramic form [14].…”
Section: Introductionmentioning
confidence: 99%
“…In this work, a blue LED CREE XT-E Royal blue is used as stimulation source. The peak wavelength of this LED is around 450 nm while the wavelength of the luminescence light is below 370 nm [5]. A combination of different filters is used to allow mainly luminescence light to pass on to the sensor.…”
Section: Methodsmentioning
confidence: 99%
“…de) For OSL, there are several possible luminophors, like CaF2 [1], BeO [2] or Al2O3 [3]. One suitable luminophore for OSL in personal dosimetry is beryllium oxide (BeO) because of its near tissue equivalent effective atomic number of 7,1 [4] [5]. The luminescence of BeO in the UV region below 370 nm, can be effectively stimulated by broadband blue light.…”
Section: Introductionmentioning
confidence: 99%
“…The reader ("BeOmax") has been developed by a group of two of the coauthors (M. S., J.H.) [13][14][15][16]. BeOs feature a linear dose response of between about 5 µGy and up to more than 5 Gy.…”
Section: Dose Measurementmentioning
confidence: 99%