2018
DOI: 10.1080/19440049.2018.1434900
|View full text |Cite
|
Sign up to set email alerts
|

Food safety traits of mussels and clams: distribution of PCBs, PBDEs, OCPs, PAHs and PFASs in sample from different areas using HRMS-Orbitrap® and modified QuEChERS extraction followed by GC-MS/MS

Abstract: Reviewing the presence of contaminant residues is important both for food safety and for monitoring of environmental pollution. Here, the occurrence of 6 polychlorinated biphenyls (PCBs), 15 organochlorine pesticides (OCPs), 7 polybrominated diphenyl ethers (PBDEs), 4 polycyclic aromatic hydrocarbons (PAHs) and 17 perfluoroalkyl substances (PFASs) was evaluated in mussels and clams. A liquid chromatography-high resolution mass spectrometry (HPLC-HRMS) and an innovative QuEChERS extraction followed by gas chrom… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
27
0
1

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
1
1

Relationship

1
6

Authors

Journals

citations
Cited by 48 publications
(31 citation statements)
references
References 24 publications
3
27
0
1
Order By: Relevance
“…After evaporation (at 35 °C in a centrifugal evaporator), the residual sample was dissolved in hexane (1 mL) and injected to a GC/MS-MS for quali-quantification of contaminants. Triple quadrupole mass spectrometry (QqQ) in electronic impact (EI) mode was used to simultaneously detect and quantify contaminants, according to the conditions described in our previous work [ 30 ]. A GC Trace 1310 chromatograph coupled to a TSQ8000 triple quadrupole mass detector (Thermo Fisher Scientific, Palo Alto, CA, USA) was used to confirm and quantify contaminants using a fused-silica capillary column Rt-5MS Crossbond-5% diphenyl 95% dimethylpolysiloxane (35 m × 0.25 mm i.d., 0.25 μm film thickness, Restek, Bellefonte, PA, USA).…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…After evaporation (at 35 °C in a centrifugal evaporator), the residual sample was dissolved in hexane (1 mL) and injected to a GC/MS-MS for quali-quantification of contaminants. Triple quadrupole mass spectrometry (QqQ) in electronic impact (EI) mode was used to simultaneously detect and quantify contaminants, according to the conditions described in our previous work [ 30 ]. A GC Trace 1310 chromatograph coupled to a TSQ8000 triple quadrupole mass detector (Thermo Fisher Scientific, Palo Alto, CA, USA) was used to confirm and quantify contaminants using a fused-silica capillary column Rt-5MS Crossbond-5% diphenyl 95% dimethylpolysiloxane (35 m × 0.25 mm i.d., 0.25 μm film thickness, Restek, Bellefonte, PA, USA).…”
Section: Methodsmentioning
confidence: 99%
“…The analysis of per-and polyfluoroalkyl substances in the fish fillet was performed as described elsewhere [7,30]. Briefly,~3 g of sample were spiked with the ISs at the concentration of 5 ng/mL and 10 mL of acetonitrile were added for extraction and protein precipitation.…”
Section: Analysis Of Per-and Polyfluoroalkyl Substances (Pfass)mentioning
confidence: 99%
See 2 more Smart Citations
“…The G. paradoxa are a suitable bio-indicator of environmental pollution (Chiesa et al, 2018;Okon et al, 2020). They can accumulate human pathogenic organisms from sewage contaminated waters and also accumulate toxins in its soft tissues through feeding on toxic phytoplankton (Gram et al, 2002).…”
Section: Introductionmentioning
confidence: 99%