2008
DOI: 10.1007/s00216-008-2400-6
|View full text |Cite
|
Sign up to set email alerts
|

Fiber-packed needle-type sample preparation device designed for gas chromatographic analysis

Abstract: A miniaturized sample preparation technique that uses a fine-fiber-packed needle as the extraction medium is reviewed, especially in relation to its application to the analysis of volatile organic compounds by gas chromatography. When the needle was packed longitudinally with a bundle of fine filaments (12 microm o.d.) which were also surface-coated with polymeric materials, successful sample preconcentration was obtained. Improved sensitivity was also established by introducing simultaneous derivatization rea… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
38
0

Year Published

2009
2009
2019
2019

Publication Types

Select...
8
1
1

Relationship

6
4

Authors

Journals

citations
Cited by 72 publications
(38 citation statements)
references
References 78 publications
0
38
0
Order By: Relevance
“…[23][24][25] In those studies, even if the retentivities to homologous analytes were different, a general trend in the selectivity between these analytes could be similar, suggesting the existence of an optimum combination of the type of polymeric coating and the fibrous material. 25,39 Based on a successful polymeric coating on the surface of Zylon fiber, confirmed as the increased retentivity to two typical non-polar analytes in Table 1, the HR-17 coating was chosen as the main coating material in following experiments.…”
Section: Retention Behavior Of Polymer-coated Fiber-packed Columnsmentioning
confidence: 99%
“…[23][24][25] In those studies, even if the retentivities to homologous analytes were different, a general trend in the selectivity between these analytes could be similar, suggesting the existence of an optimum combination of the type of polymeric coating and the fibrous material. 25,39 Based on a successful polymeric coating on the surface of Zylon fiber, confirmed as the increased retentivity to two typical non-polar analytes in Table 1, the HR-17 coating was chosen as the main coating material in following experiments.…”
Section: Retention Behavior Of Polymer-coated Fiber-packed Columnsmentioning
confidence: 99%
“…Alternative sample preparation techniques have been developed as a needle-type sample preparation device. [7][8][9][10][11][12][13][14][15] Compared to the conventional SPME, the needle-type sampling device has been regarded to have good mechanical strength and high extraction capacity. In our previous work, a polymer particulate medium based on a copolymer of methacrylic acid (MA) and ethylene glycol dimethacrylate (EDMA) was synthesized, and packed into a specially-designed needle as the extraction medium.…”
Section: Introductionmentioning
confidence: 99%
“…Packed into a specially-designed needle, polymeric particles and filaments could be employed as the extraction medium [75][76][77][78]. In-needle derivatization methods were developed for several target analytes with a fiber-packed needle.…”
Section: Needle-type Sample Preparation Devicementioning
confidence: 99%