A flexible and wearable amperometoric glucose sensor was fabricated and tested. Also, the sensor was utilized to tear glucose monitoring. The sensor was constructed by immobilizing GOD onto a flexible oxygen electrode (Pt working electrode and Ag/AgCl counter/reference electrode), which was fabricated using "Soft-MEMS" techniques onto a functional polymer membrane. In purpose of bioinstrumentation, adhesive agents were not used for constructing the flexible biosensor. Linear relationship between glucose concentration and output current was obtained in a range of 0.025-1.475 mmol/l, with a correlation coefficient of 0.998. Current dependences on pH and temperature were also evaluated. The current was largest at pH 7.0 and the current increased when temperature increased. This indicates that the output current depends on enzyme activity. Based on the basic characteristics investigation, the glucose sensor was applied to measurement of glucose in tear fluids on an eye site of a Japan white rabbit. The change of tear glucose level induced by oral-administration of glucose was monitored as a current change of the sensor attached on the eye site. In this investigation, the tear glucose level varied from 0.16 to 0.46 mmol/l. Although there was a delay of several tens of minutes towards blood sugar level, it is considered to be possible that non-invasive continuous glucose monitoring can be realized using the flexible biosensor.
BackgroundBecause the primary aim of infertility treatment is to achieve pregnancy, mental health care during this treatment is often neglected. However, the inability to conceive children is stressful for couples throughout the world. Thus, the purpose of this study was to investigate factors related to the anxiety and depression of female infertility patients.MethodsParticipants included 83 Japanese women who initially visited the Reproduction Center of the Tokyo Dental College Ichikawa General Hospital to undergo testing and receive infertility treatment between February and April 2008. We administered two psychological tests, the Self-rating Depression Scale (SDS) test and the Hospital Anxiety and Depression Scale (HADS) test. We then examined the association of the test results with age, pregnancy and delivery history, employment status, duration of infertility, infertility treatment history, and male infertility.ResultsAs patient age increased, total HADS and depression scores also increased. No correlation was observed between duration of infertility and SDS or HADS scores. Results were similar when the presence and absence of delivery history was compared. Patients who underwent infertility treatment were more likely to have high HADS depression scores compared to patients who had not undergone treatment. Additionally, patients whose husbands were infertile had significantly lower total HADS and anxiety scores than those whose husbands were not infertile.ConclusionsAge and male infertility are factors that influence the presence of anxiety and depression in female infertility patients.
A single-photon avalanche diode (SPAD) with enhanced near-infrared (NIR) sensitivity has been developed, based on 0.18 μm CMOS technology, for use in future automotive light detection and ranging (LIDAR) systems. The newly proposed SPAD operating in Geiger mode achieves a high NIR photon detection efficiency (PDE) without compromising the fill factor (FF) and a low breakdown voltage of approximately 20.5 V. These properties are obtained by employing two custom layers that are designed to provide a full-depletion layer with a high electric field profile. Experimental evaluation of the proposed SPAD reveals an FF of 33.1% and a PDE of 19.4% at 870 nm, which is the laser wavelength of our LIDAR system. The dark count rate (DCR) measurements shows that DCR levels of the proposed SPAD have a small effect on the ranging performance, even if the worst DCR (12.7 kcps) SPAD among the test samples is used. Furthermore, with an eye toward vehicle installations, the DCR is measured over a wide temperature range of 25–132 °C. The ranging experiment demonstrates that target distances are successfully measured in the distance range of 50–180 cm.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.