1992
DOI: 10.1016/0378-4347(92)80474-5
|View full text |Cite
|
Sign up to set email alerts
|

Fast liquid chromatography for the determination of drugs in plasma and combination with liquid—solid extraction in a fully automated system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

1992
1992
2007
2007

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 8 publications
(5 citation statements)
references
References 9 publications
0
5
0
Order By: Relevance
“…Concentrations of TCBZ and metabolites in plasma were measured by h.p.l.c. [7]. The limit of quantification was 0.06 μmol l −1 (0.02 μg ml −1 ) for TCBZ, 0.13 μmol l −1 (0.05 μg ml −1 ) for TCBZ‐SO and 0.05 μmol l −1 (0.02 μg ml −1 ) for TCBZ‐SO2.…”
Section: Methodsmentioning
confidence: 99%
“…Concentrations of TCBZ and metabolites in plasma were measured by h.p.l.c. [7]. The limit of quantification was 0.06 μmol l −1 (0.02 μg ml −1 ) for TCBZ, 0.13 μmol l −1 (0.05 μg ml −1 ) for TCBZ‐SO and 0.05 μmol l −1 (0.02 μg ml −1 ) for TCBZ‐SO2.…”
Section: Methodsmentioning
confidence: 99%
“…Rouan et al [154] described an automated C 18 clean-up procedure for isolation of TCB residues on an ASPEC system. They demonstrated, with a limited number of samples, that recovery values greater than 90% could be obtained under optimal conditions.…”
Section: Plasma Serum or Other Biological Fluidsmentioning
confidence: 99%
“…Rouan et al separated TCB, TCB-SO, TCB-SO 2 and an internal standard on a short C 18 column (33 mm × 4.6 mm) in less than 10 min [154]. Porter and Johnston [232] evaluated narrow bore columns (2.1 mm) for determination of TBZ, MBZ, ABZ and FBZ residues.…”
Section: Liquid Chromatography Based Separationsmentioning
confidence: 99%
“…The robotic method was adopted from a manual HPLC method (Rouan et al, 1991). Utilization of a laboratory robotic system eliminates the tedium of the sample preparation procedure, improves safety by ensuring minimal exposure to biolo- gical samples, and frees the analyst to perform other duties, by leaving only the replenishment of disposables (tubes, caps and pipette tips) and filling of reagent reservoirs.…”
Section: Discussionmentioning
confidence: 99%
“…The manual method involving liquid-liquid extraction previously described for the assay of CGP 33101 in plasma (Rouan et al, 1991) has been reproduced by the robotic system with minor modifications. The entire system provides unattended sample preparation and analysis, as well as automated retrieval and computation of the chromatographic results. )…”
Section: Introductionmentioning
confidence: 99%