2016
DOI: 10.1016/j.jchromb.2016.06.007
|View full text |Cite
|
Sign up to set email alerts
|

Fast high-throughput screening of angiotensin-converting enzyme insertion/deletion polymorphism by variable programmed electric field strength-based microchip electrophoresis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
9
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(9 citation statements)
references
References 34 publications
0
9
0
Order By: Relevance
“…However, the PCR products were introduced into three parallel channels (multichannel chip 1, Figure (b)) and five parallel channels (multichannel chip 2, Figure (c)) separately. As the fabrication of multichannel microchip 1 was not same as those of the other two types regarding detection points and channel lengths, the separation conditions were slightly different . In both of the multichannel microchips, different genotypes with 10 PCR cycles and 35 cycles could be detected simultaneously in a short‐time (<25 s) without loss of resolving power ( R s ≥ 1.8), and the S / N ratio increased with increasing number of PCR cycles (Figures and S3, Tables S2 and S3).…”
Section: Application Of the Me‐pefs Methods To Human Bloodmentioning
confidence: 99%
See 1 more Smart Citation
“…However, the PCR products were introduced into three parallel channels (multichannel chip 1, Figure (b)) and five parallel channels (multichannel chip 2, Figure (c)) separately. As the fabrication of multichannel microchip 1 was not same as those of the other two types regarding detection points and channel lengths, the separation conditions were slightly different . In both of the multichannel microchips, different genotypes with 10 PCR cycles and 35 cycles could be detected simultaneously in a short‐time (<25 s) without loss of resolving power ( R s ≥ 1.8), and the S / N ratio increased with increasing number of PCR cycles (Figures and S3, Tables S2 and S3).…”
Section: Application Of the Me‐pefs Methods To Human Bloodmentioning
confidence: 99%
“…The sample injection was performed by applying the same potential discussed above. As the fabrication of multichannel chip 1 was different from that of the single‐channel chip, the separation process was set as 615 V/cm, 0–22.5 s; 231 V/cm, 22.5–28.5 s; and 615 V/cm, 28.5–40 s . After each run, the microchip was rinsed with pure water for 10 min.…”
Section: Methodsmentioning
confidence: 99%
“…Acute myocardial infarction [122,123], coronary artery disease [124][125][126][127][128], and hypertension [129] were investigated.…”
Section: Cardiovascular Diseasesmentioning
confidence: 99%
“…The insertion and deletion polymorphism in the angiotensin-converting enzyme gene is associated with hypertension. A strategy of MGE-LIF using an electric-field gradient was explored for mutation detection in the Alu element of the angiotensin-converting enzyme gene [129]. The target DNA had a length of 190 bp and 490 bp after deletion and insertion, respectively.…”
Section: Hypertensionmentioning
confidence: 99%
“…Rigat et al were the rst to describe a method for the detection of I/D polymorphisms using polymerase chain reaction (PCR) and agarose gel electrophoresis [1,2]. Other techniques including real-time polymerase chain reaction (RT-PCR) [3][4][5], high resolution melting (HRM) [6,5], polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP) [7] and microchip electrophoresis (ME) system [8] have also been used to detect I/D polymorphism. However, these techniques require tedious experimental procedures and expensive and sophisticated instruments that may not be available in clinical institutions.…”
Section: Introductionmentioning
confidence: 99%