2019
DOI: 10.1016/j.ultsonch.2019.04.008
|View full text |Cite
|
Sign up to set email alerts
|

Facile synthesis of mesoporous WS2 nanorods decorated N-doped RGO network modified electrode as portable electrochemical sensing platform for sensitive detection of toxic antibiotic in biological and pharmaceutical samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
20
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 42 publications
(23 citation statements)
references
References 45 publications
1
20
0
Order By: Relevance
“…The electrochemical behavior of bare SPCE, CoMn 2 O 4 -400/SPCE, CoMn 2 O 4 -500/SPCE, and CoMn 2 O 4 -600/SPCE was investigated in the presence of 100 μM RXS at the scan rate of 0.05 V s –1 , as shown in Figure B. The electrocatalytic reduction mechanism of RXS is schematized in Scheme based on the literature . After injection of RXS, a prominent reduction peak in the CV curves is observed for bare SPCE, CoMn 2 O 4 -400/SPCE, CoMn 2 O 4 -500/SPCE, and CoMn 2 O 4 -600/SPCE.…”
Section: Resultssupporting
confidence: 72%
See 4 more Smart Citations
“…The electrochemical behavior of bare SPCE, CoMn 2 O 4 -400/SPCE, CoMn 2 O 4 -500/SPCE, and CoMn 2 O 4 -600/SPCE was investigated in the presence of 100 μM RXS at the scan rate of 0.05 V s –1 , as shown in Figure B. The electrocatalytic reduction mechanism of RXS is schematized in Scheme based on the literature . After injection of RXS, a prominent reduction peak in the CV curves is observed for bare SPCE, CoMn 2 O 4 -400/SPCE, CoMn 2 O 4 -500/SPCE, and CoMn 2 O 4 -600/SPCE.…”
Section: Resultssupporting
confidence: 72%
“…The LOD and the sensitivity of the CoMn 2 O 4 -500-modified electrode are calculated based on the following formulas and The LOD and the sensitivity of the CoMn 2 O 4 -500-based electrochemical sensor are calculated to be 0.002 μM and 33.13 μA μM –1 cm –2 , respectively. Table shows the electroanalytical performance comparison of the CoMn 2 O 4 -500 material with other electrode materials reported in the literature for the RXS detection. ,, The comparison results show that the proposed CoMn 2 O 4 -500 material is much better than most of other electrode materials. The superior electrocatalytic performance of the CoMn 2 O 4 -500-based electrochemical sensor for the RXS detection can be well interpreted by abundant active sites, high conductivity, unique structure, large specific surface area, and rapid transportation.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations