1993
DOI: 10.1016/0003-2670(93)80185-n
|View full text |Cite
|
Sign up to set email alerts
|

Enzyme amperometric sensor for the determination of cholinesterase inhibitors or activators

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
2
0

Year Published

1995
1995
2016
2016

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(2 citation statements)
references
References 10 publications
0
2
0
Order By: Relevance
“…[223][224][225] MFE's have been used in hyphenated electrochemicalspectroscopic methods as preconcentrating devices for atomic spectroscopy [226][227][228][229][230] and chemiluminescence 231 as well as in thin-layer chromatography-stripping voltammetry 232,233 and anion exchange-stripping voltammetry. 234 Kinetic studies of enzyme inactivation, 235,236 the effect of metals on enzyme activity 237 and kinetic separations 238 on MFE's have been reported. MFE's have been applied to the indirect determination of surfactants, 239,240 EDTA, 241 oxygen 242 and thorium and scandium.…”
Section: Selected Applications Of Mfe'smentioning
confidence: 99%
“…[223][224][225] MFE's have been used in hyphenated electrochemicalspectroscopic methods as preconcentrating devices for atomic spectroscopy [226][227][228][229][230] and chemiluminescence 231 as well as in thin-layer chromatography-stripping voltammetry 232,233 and anion exchange-stripping voltammetry. 234 Kinetic studies of enzyme inactivation, 235,236 the effect of metals on enzyme activity 237 and kinetic separations 238 on MFE's have been reported. MFE's have been applied to the indirect determination of surfactants, 239,240 EDTA, 241 oxygen 242 and thorium and scandium.…”
Section: Selected Applications Of Mfe'smentioning
confidence: 99%
“…Moreover, the use of electrochemistry makes it possible for us to draw some conclusions regarding the mechanism of macromolecule-involving processes, particularly regarding DNA behavior both in solution and at the surface of the electrode. The latter simulates the properties of DNA in a cell membrane. , In ref , it was suggested to employ enzyme modulator-mediated immunoassay involving a cholinesterase (ChE)-based amperometric electrode for the determination of antibodies to DNA and AMD diagnosis, which takes the autoimmune origin of the disease into consideration, with organophosphorus inhibitors covalently bound to DNA used as modulators.…”
mentioning
confidence: 99%