Direct analysis of wines from the province of Lower Silesia (Poland) by microplasma source optical emission spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(6 citation statements)
references
References 23 publications
0
6
0
Order By: Relevance
“…These values are similar or slightly worse compared to that obtained by our group in previous studies. 28,29 The small differences between the DLs obtained in these three works likely resulted from the slightly different operating conditions (which affected not only the signal intensities but also the background level in the vicinity of the analytical lines) as well as tubes of different diameters applied in this work, which we know from our expercience to slightly affect the signal intensities. Comparing the obtained DLs of Zn, Mg, Ca, Na, and K with the values reported by other researchers for similar FLC-APGD systems (see Table 1), it can be noticed that the DLs of the elements obtained herein are on average 1 order of magnitude better than those published in the majority of recently published papers.…”
Section: Analytical Performancementioning
confidence: 92%
See 3 more Smart Citations
“…These values are similar or slightly worse compared to that obtained by our group in previous studies. 28,29 The small differences between the DLs obtained in these three works likely resulted from the slightly different operating conditions (which affected not only the signal intensities but also the background level in the vicinity of the analytical lines) as well as tubes of different diameters applied in this work, which we know from our expercience to slightly affect the signal intensities. Comparing the obtained DLs of Zn, Mg, Ca, Na, and K with the values reported by other researchers for similar FLC-APGD systems (see Table 1), it can be noticed that the DLs of the elements obtained herein are on average 1 order of magnitude better than those published in the majority of recently published papers.…”
Section: Analytical Performancementioning
confidence: 92%
“…30,31 Moreover, similar to ICP-OES, FLC-APGD-OES enables the analysis of the content of many different elements in samples. 32–35 Owing to all these advantages, the FLC-APGD-OES method has been successfully applied for the analysis of different samples with complex matrices, such as blood, 36 honey, 37 human hair, 38 fruit juices, 28 soils, 33 and wines 29 as well as samples with simpler matrices such as different types of water. 39–45…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…The SCGD has been used to quantitate elemental composition at trace and ultra-trace levels in a wide variety of sample types including silica colloids, 9 nanoparticles, 10 bottled water, 11 wastewaters, 12 honey, 13 and wine. 14 It has also found use with hydride generation, 15 water remediation, 16,17 and nanoparticle synthesis. 18 Because the SCGD-AES is a relatively nascent technique, a variety of methods and geometries have been reported to improve the analytical gures of merit of the technique.…”
Section: Introductionmentioning