A novel chemical ionization source for organic mass spectrometry is introduced. This new source uses a glow discharge in the flowing afterglow mode for the generation of excited species and ions. The direct-current gas discharge is operated in helium at atmospheric pressure; typical operating voltages and currents are around 500 V and 25 mA, respectively. The species generated by this atmospheric pressure glow discharge are mixed with ambient air to generate reagent ions (mostly ionized water clusters and NO+), which are then used for the ionization of gaseous organic compounds. A wide variety of substances, both polar and nonpolar, can be ionized. The resulting mass spectra generally show the parent molecular ion (M+ or MH+) with little or no fragmentation. Proton transfer from ionized water clusters has been identified as the main ionization pathway. However, the presence of radical molecular ions (M+) for some compounds indicates that other ionization mechanisms are also involved. The analytical capabilities of this source were evaluated with a time-of-flight mass spectrometer, and preliminary characterization shows very good stability, linearity, and sensitivity. Limits of detection in the single to tens of femtomole range are reported for selected compounds.
The flowing afterglow-atmospheric pressure glow discharge (APGD) ionization source described in part 1 of this study (in this issue) is applied to the direct analysis of condensed-phase samples. When either liquids or solids are exposed to the ionizing beam of the APGD, strong signals for the molecular ions of substances present on their surfaces can be detected without compromising the integrity of the solid sample structure or sample substrate. As was observed for gas-phase compounds in part 1 of this study, both polar and nonpolar substances can be ionized and detected by mass spectrometry. The parent molecular ion (or its protonated counterpart) is usually the main spectral feature, with little or no fragmentation in evidence. Preliminary quantitative results show that this approach offers very good sensitivity (detection limits in the picogram regime are reported for several test compounds in part 1 of this study) and linear response to the analyte concentration. Examples of the application of this strategy to the analysis of real-world samples, such as the direct analysis of pharmaceutical compounds or foods is provided. The ability of this source to perform spatially resolved analysis is also demonstrated. Preliminary studies of the mechanisms of the reactions involved are described.
Two relatively new ambient ionization sources, direct analysis in real time (DART) and the flowing atmospheric-pressure afterglow (FAPA), use direct current, atmospheric-pressure discharges to produce reagent ions for the direct ionization of a sample. Although at a first glance these two sources appear similar, a fundamental study reveals otherwise. Specifically, DART was found to operate with a corona-to-glow transition (C-G) discharge whereas the FAPA was found to operate with a glow-to-arc transition (G-A) discharge. The characteristics of both discharges were evaluated on the basis of four factors: reagent-ion production, response to a model analyte (ferrocene), infrared (IR) thermography of the gas used for desorption and ionization, and spatial emission characteristics. The G-A discharge produced a greater abundance and a wider variety of reagent ions than the C-G discharge. In addition, the discharges yielded different adducts and signal strengths for ferrocene. It was also found that the gas exiting the discharge chamber reached a maximum of 235°C and 55°C for the G-A and C-G discharges, respectively. Finally, spatially resolved emission maps of both discharges showed clear differences for N 2 ϩ and O(I). These findings demonstrate that the discharges used by FAPA and DART are fundamentally different and should have different optimal applications for ambient desorption/ionization mass spectrometry (ADI-MS). irect-current (DC) discharges have been widely used for elemental analyses since they were first introduced for alloy characterization [1]. When DC discharges were coupled with mass spectrometry, the result was a very sensitive and powerful tool for elemental [1] and molecular analyses [2,3]. Of the many electrical regimes of DC discharges, three forms have been found to have particular analytical merit: the arc, the glow, and the corona. Among these three types of discharges, the fundamental distinction is the operating current and voltage. The arc occurs at very high currents (hundreds of amperes) with a low voltage drop between electrodes (tens of volts). It also exhibits negative resistance; that is, the sustaining voltage drops as the current rises. The glow discharge (GD), which has conventionally been operated between 0.1 to 10 Torr, exists at much lower currents (tens of milliamperes) and a higher voltage drop (hundreds of volts). Lastly, the corona discharge operates with very low currents (a few microamperes) and a much higher voltage drop (several kilovolts).Corona discharges find their most common analytical application in atmospheric pressure chemical ionization (APCI) [4,5]. In conventional APCI, a corona discharge is formed by applying ϳ4 kV to a needle electrode in a selected atmosphere, to yield currents of ϳ5 A. After a series of reactions [5], reagent ions are produced that can then ionize a sample. Protonated water clusters are typically observed because of the presence of water vapor in the air. Such protonated clusters promote proton transfer ionization, resulting in mass spect...
A plasma-based ambient desorption/ionization mass spectrometry (ADI-MS) source was used to perform molecular mass spectral imaging. A small amount of sample material was ablated by focusing 266 nm laser light onto a spot. The resulting aerosol was transferred by a nitrogen stream to the flowing afterglow of a helium atmospheric pressure glow discharge ionization source; the ionized sample material was analyzed by a Leco Unique time-of-flight mass spectrometer. Two-dimensional mass spectral images were generated by scanning the laser beam across a sample surface. The total analysis time for a 6 mm2 surface, which is limited by the washout of the ablation chamber, was less than 30 min. With this technique, a spatial resolution of ∼20 μm has been achieved. Additionally, the laser ablation configuration was used to obtain depth information of over 2 mm with a resolution of ∼40 μm. The combination of laser ablation with the flowing atmospheric pressure afterglow source was used to analyze several sample surfaces for a wide variety of analytes and with high sensitivity (LOD of 5 fmol for caffeine).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.