2016
DOI: 10.1149/2.0661608jes
|View full text |Cite
|
Sign up to set email alerts
|

Differential Pulse Voltammetric Determination of Albendazole and Mebendazole in Pharmaceutical Formulations Based on Modified Sonogel Carbon Paste Electrodes with Perovskite-Type LaFeO3Nanoparticles

Abstract: Differential pulse voltammetric determination of albendazole and mebendazole in pharmaceutical formulations based on modified sonogel carbon paste electrodes with Perovskite-type LaFeO3 nanoparticles.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

2
18
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 19 publications
(20 citation statements)
references
References 26 publications
(93 reference statements)
2
18
0
Order By: Relevance
“…Mineral oil, Carbon graphite, Palladium oxide and Titanium IV Isopropoxide were purchased from (Sigma-Aldrich, St. Louis, MO, USA). Perovskite-Type LaFeO3 herein employed was produced and characterized according to previously described protocol [4].…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Mineral oil, Carbon graphite, Palladium oxide and Titanium IV Isopropoxide were purchased from (Sigma-Aldrich, St. Louis, MO, USA). Perovskite-Type LaFeO3 herein employed was produced and characterized according to previously described protocol [4].…”
Section: Methodsmentioning
confidence: 99%
“…All pro-portions are listed in Table 1. The modifications herein employed were subjected to scanning electron microscopy and elemental characterization in previous works by our group [4,5]. The experimental conditions for CV were: scan rate (υ) of either: 12.5; 25; 50; 100; 250 or 500 mV s -1 , and scan range of -0.5 to 1.0.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Various analytical method is found for the assay of MBZ in different formulation dosage including UV-visible spectrometry (3-7), highperformance liquid chromatography (8-11), selective membrane sensor (12-14) and potentiometric analysis (14). The present work stand on oxidation of hydrolyzed MBZ in the presence of NBS then coupling with 4-BA to get a paled orang complex absorbed at 434 nm at pH 9.…”
Section: Introductionmentioning
confidence: 99%
“…However, these techniques are limited by the low reproducibility, and there is a clear need to evaluate and propose the use of sensors that are easy to clean and that guarantee the recognized advantages of electroanalysis. Hence, the use of graphite pencil electrodes (GPE) has proven to be a useful and efficient and low cost tool for the determination of drugs in pharmaceutical formulations, without many of the drawbacks found in other methods [4][5][6].…”
Section: Introductionmentioning
confidence: 99%