This work details the study of the redox behavior of the drugs cyclobenzaprine (CBP), amitriptyline (AMP) and nortriptyline (NOR) through voltammetric methods and computational chemistry. Results obtained in this study show that the amine moiety of each compound is more likely to undergo oxidation at 1a at Ep1a ≈ 0.69, 0.79, 0.93 V (vs. Ag/AgCl/KClsat) for CBP, AMP and NOR, respectively. Moreover, CBP presented a second peak, 2a at Ep2a ≈ 0.98 V (vs. Ag/AgCl/KClsat) at pH 7.0. Furthermore, the electronic structure calculation results corroborate the electrochemical assays regarding the HOMO energies of the lowest energy conformers of each molecule. The mechanism for each anodic process is proposed according to electroanalytical and computational chemistry findings, which show evidence that the methods herein employed may be a valuable alternative to study the redox behavior of structurally similar drugs.
Diclofenac (DIC) is a non-steroidal anti-inflammatory drug of wide use around the world. Electroanalytical methods display a high analytical potential for application in pharmaceutical samples but the drawbacks concerning electrode fouling and reproducibility are of major concern. Henceforth, the aim of this work was to propose the use of alternative low-cost carbon black (CB) and ionic liquid (IL) matrix to modify the surface of pencil graphite electrodes (PGE) in order to quantify DIC in raw materials, intermediates, and final products, as well as in stability assays of tablets. The proposed method using CB+IL/PGE displayed good recovery (99.4%) as well as limits of detection (LOD) of 0.08 µmol L-1 and limits of quantification (LOQ) of 0.28 µmol L−1. CB+IL/PGE response was five times greater than the unmodified PGE. CB+IL-PGE stands as an interesting alternative for DIC assessment in different pharmaceutical samples.
Abstract:The development of sensors and biosensors based on copper enzymes and/or copper oxides for phenol sensing is disclosed in this work. The electrochemical properties were studied by cyclic and differential pulse voltammetry using standard solutions of potassium ferrocyanide, phosphate/acetate buffers and representative natural phenols in a wide pH range (3.0 to 9.0). Among the natural phenols herein investigated, the highest sensitivity was observed for rutin, a powerful antioxidant widespread in functional foods and ubiquitous in the plant kingdom. The calibration curve for rutin performed at optimum pH (7.0) was linear in a broad concentration range, 1 to 120 µM (r = 0.99), showing detection limits of 0.4 µM. The optimized biomimetic sensor was also applied in total phenol determination in natural samples, exhibiting higher stability and sensitivity as well as distinct selectivity for antioxidant compounds.
Piroxicam (PRX) was determined in pharmaceutical capsules with differential pulse voltammetry (DPV) in a three electrode system consisting of a pencil graphite electrode (PGE) as working electrode, a Pt wire and a reference electrode of Ag/AgCl/KCl 3 M. An irreversible oxidation peak was observed in E pa c.a. 0.6 V, which correlates to the oxidation of PRX. The coefficient of linear correlation obtained was 0.9946, with limit of detection of 2.1 µM and limit of quantification of 4.7 µM. PGE assays showed good analytical performance compared to high performance liquid chromatography and spectrophotometry, showing the potential to be further developed and employed in quick and simple analyses.
Over the years, Electroanalysis has been widely applied to elucidate redox behavior of novel molecules. The selectivity and low cost are spotlight features in pharmacopeial methods of identification, that can be reached by voltammetric approaches. In this work, differential pulse voltammetric (DPV) profile and the slope of the linear regression obtained from calibration graphs along with the scan study are proposed as new perspective of identification assays. With the proposed methodology we were able to identify the similarities among DPV profile and the slopes obtained for each tablet. In addition, this new technology was successfully employed to identify the following chemicals: Paracetamol (PAR), Promethazine (PMZ), Diclofenac (DIC), Piroxicam (PRX), Indomethacin (IND) and Cyclobenzaprine (CBP) in pharmaceutical assays using Pencil Graphite Electrodes. Furthermore, our new methodology was effectively compared to Raman Spectroscopy for the analysis of the range of chemicals in the pharmaceutical assays.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.