2006
DOI: 10.1016/j.talanta.2005.07.027
|View full text |Cite
|
Sign up to set email alerts
|

Determination of total mercury in biological samples using flow injection CVAAS following tissue solubilization in formic acid

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
19
0

Year Published

2007
2007
2023
2023

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 34 publications
(20 citation statements)
references
References 12 publications
1
19
0
Order By: Relevance
“…Also the use of formic acid in similar applications has provided good results. 17,29 As shown in this work (Table 1), similar results in the medium of TMAH were obtained by analysis of processed meats using acid digestion and formic acid solubilization. The concentrations obtained using the three different methods of sample preparation are in agreement for all the studied analytes, the values of the concentrations obtained with the respective methods did not vary more than 5%.…”
Section: Comparison Of Sample Preparation Proceduressupporting
confidence: 86%
“…Also the use of formic acid in similar applications has provided good results. 17,29 As shown in this work (Table 1), similar results in the medium of TMAH were obtained by analysis of processed meats using acid digestion and formic acid solubilization. The concentrations obtained using the three different methods of sample preparation are in agreement for all the studied analytes, the values of the concentrations obtained with the respective methods did not vary more than 5%.…”
Section: Comparison Of Sample Preparation Proceduressupporting
confidence: 86%
“…The determination of Hg and MeHg in seafood samples has been done using many tecniques [3][4][5][6] and the quality of the results can be guarantee by the use of certified reference materials (CRMs).…”
Section: Introductionmentioning
confidence: 99%
“…In addition, it can be used in closed flasks and in most cases without the need of external energy for solubilization of the samples, while the assistance of ultrasound can be used to reduce acid consumption and sample preparation time. [25][26][27][28][29] Considering the importance of certain analytical data to both consumers and health professionals, and also the recent legislations for Na concentration in foods, this work focus on the sample preparation of meat based products in order to simplify the procedures available for the determination of Na and K by atomic spectrometric techniques. For this purpose, two methods were evaluated to prepare a slurry sample: (i) using the alkaline solubilization with TMAH and (ii) using acidic solubilization with formic acid in order to determine the better alternative method in relation to the conventional procedures of mineralization.…”
Section: Introductionmentioning
confidence: 99%