2011
DOI: 10.1016/j.talanta.2011.04.047
|View full text |Cite
|
Sign up to set email alerts
|

Determination of parabens in shampoo using high performance liquid chromatography with amperometric detection on a boron-doped diamond electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

5
35
0
3

Year Published

2012
2012
2021
2021

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 77 publications
(43 citation statements)
references
References 29 publications
5
35
0
3
Order By: Relevance
“…The reason for this phenomenon can be a decrease of viscosity of the mixed solvent (from 1.322 to 1.061 mPa s for HAc and its mixture with 20 % AN, respectively) and thus the increase of the diffusion coefficient for MP. These observations confirm the results obtained by Martins et al [8] during the anodic oxidation of parabens in aqueous solutions. An addition of AN to HAc causes simultaneously a considerable increase of the specific conductivity, v of the solutions (from 9.2 to.…”
Section: Choice Of the Solution Compositionsupporting
confidence: 93%
See 3 more Smart Citations
“…The reason for this phenomenon can be a decrease of viscosity of the mixed solvent (from 1.322 to 1.061 mPa s for HAc and its mixture with 20 % AN, respectively) and thus the increase of the diffusion coefficient for MP. These observations confirm the results obtained by Martins et al [8] during the anodic oxidation of parabens in aqueous solutions. An addition of AN to HAc causes simultaneously a considerable increase of the specific conductivity, v of the solutions (from 9.2 to.…”
Section: Choice Of the Solution Compositionsupporting
confidence: 93%
“…Esters of p-hydroxybenzoic acid (PHB), commonly known as parabens, are extensively used as preservatives in pharmaceuticals [1][2][3][4], cosmetics [1][2][3][5][6][7][8][9], and foodstuffs [1][2][3][10][11][12][13]. Their molecular structures are shown in Scheme 1.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…Several hundreds of reviews [26], [27] and [28] were published on applications of these electrodes in cyclic voltammetry for the analysis of pesticides, herbicides, pharmaceutical products [29], [30] and [31]. The conductive diamond was also used to manufacture electrodes for electrochemical detection in HPLC and flow injection [32], [33], [34], [35], [36], [37] and [38] electrochemical reactions [39].…”
Section: Introductionmentioning
confidence: 99%