Detection of multi-β-agonist residues in liver matrix by use of a surface plasma resonance biosensor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
33
1

Year Published

2005
2005
2019
2019

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 66 publications
(34 citation statements)
references
References 16 publications
0
33
1
Order By: Relevance
“…However, our LOD was larger than the previous ones reported by Li and coworkers [21] using a homemade SPR instrument and by Traynor and coworkers [22] using BIACORE Q. This can be explained by differences in the measurement processes of the two instruments.…”
Section: Clen Detectioncontrasting
confidence: 88%
See 2 more Smart Citations
“…However, our LOD was larger than the previous ones reported by Li and coworkers [21] using a homemade SPR instrument and by Traynor and coworkers [22] using BIACORE Q. This can be explained by differences in the measurement processes of the two instruments.…”
Section: Clen Detectioncontrasting
confidence: 88%
“…Relationship between the shift in resonance wavelength (dk 2 ) and the concentration of CLEN (target analyte) in the mixture. experiment requires much smaller volumes of samples (10 ll) at higher concentrations, whereas higher sample volumes at lower concentrations are injected into the liquid flow systems of Li and coworkers [21] and Traynor and coworkers [22]. Because of the features of multichannel measurement and the new bioprobe immobilization strategy, the developed method is suitable for fast screening of a large number of samples.…”
Section: Clen Detectionmentioning
confidence: 99%
See 1 more Smart Citation
“…These methods include liquid chromatography (Chang, Chou, & Hwang, 2005;Meng et al, 2012;Turberg, Macy, Lewis, & Coleman, 1994), gas chromatography (Bocca, Fiori, Cartoni, & Brambilla, 2003), liquid chromatography tandem mass spectrometry (LC-MS/MS) (Shishani, Chai, Jamokha, Aznar, & Hoffman, 2003;Wu, Liu, & Peng, 2014), gas chromatography-mass spectrometry (Montrade, Lebizec, Monteau, & Andre, 1995;Wang, Li, Zhang, & Shen, 2006), enzyme-linked immunoassay (Hahnau & Julicher, 1996;Harkins, Woods, Lehner, Fisher, & Tobin, 2001;Pinheiro et al, 2008), colloidal gold test strip (Khamta, Pattarawarapan, Nangola, & Tayapiwatana, 2009;Zhang et al, 2009), surface plasmon resonance immunosensors (Traynor, Crooks, Bowers, & Elliott, 2003), and electrochemical immunosensors (He, Wang, Zhang, & Yang, 2009). Table 1 Chemical formula, accurate mass, retention time and characteristic fragment ions of 32 b-agonists.…”
Section: Introductionmentioning
confidence: 99%
“…A high-affinity, broadspectrum ␤-agonist monoclonal antibody was applied in a SPR immuno-biosensor competitive assay (Fig. 1D) [106]. Also in this case, the sample treatment was quite complex and included proteolytic digestion, enzymatic deconjugation and solid-phase extraction.…”
Section: 319ˇ-agonistmentioning
confidence: 99%