1995
DOI: 10.1016/0003-2670(95)00213-j
|View full text |Cite
|
Sign up to set email alerts
|

Detection of mixtures of organic pollutants in water by polymer film receptors in fibre-optical sensors based on reflectometric interference spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
16
0

Year Published

1996
1996
2020
2020

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 31 publications
(16 citation statements)
references
References 12 publications
0
16
0
Order By: Relevance
“…Pollutants can be detected in the gaseous and liquid phases [252]. The lack of selectivity of polymers towards specific compounds can be overcome by application of multivariate data analysis [250,251] or curve fitting techniques applied to the time-resolved signals [448]. The combination of an interferometric measurement of the swelling of a polymer with the color change of a doped indicator dye allows the determination of ammonia and a perhalogenated compound using only one sensor element [171].…”
Section: Swellingmentioning
confidence: 99%
“…Pollutants can be detected in the gaseous and liquid phases [252]. The lack of selectivity of polymers towards specific compounds can be overcome by application of multivariate data analysis [250,251] or curve fitting techniques applied to the time-resolved signals [448]. The combination of an interferometric measurement of the swelling of a polymer with the color change of a doped indicator dye allows the determination of ammonia and a perhalogenated compound using only one sensor element [171].…”
Section: Swellingmentioning
confidence: 99%
“…Especially, it was difficult to achieve quick responses in aqueous solution. In this paper we would like to present molecularly imprinted polymers containing benzamidine groups (see Structure 1) as sensitive layers on transducers used for the optical measurement technique reflectometric interference spectroscopy (RIfS) [17,18,19] in the aqueous phase. By time-dependent detection of changes in the optical thickness (n×d) of thin polymer films (<100 nm) an interaction between the MIP and analyte molecules can be monitored.…”
Section: Introductionmentioning
confidence: 99%
“…Existing universal CE detectors include micro-interferometric backscatter detector, 7 refractive index detector, [8][9][10][11][12] thermoptical absorbance detector, 13 condensation nucleation light-scattering detector, 14 and a recent one based on thermally induced capillary vibrations. 15 All of these are optical techniques, which require light sources and photodetectors, and careful optical alignment.…”
Section: Introductionmentioning
confidence: 99%