2018
DOI: 10.1155/2018/3726207
|View full text |Cite
|
Sign up to set email alerts
|

Design and Implementation Guidelines for a Modular Spectral-Domain Optical Coherence Tomography Scanner

Abstract: In the past decades, spectral-domain optical coherence tomography (SD-OCT) has transformed into a widely popular imaging technology which is used in many research and clinical applications. Despite such fast growth in the field, the technology has not been readily accessible to many research laboratories either due to the cost or inflexibility of the commercially available systems or due to the lack of essential knowledge in the field of optics to develop custom-made scanners that suit specific applications. T… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2018
2018
2021
2021

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 10 publications
(8 citation statements)
references
References 84 publications
(118 reference statements)
0
8
0
Order By: Relevance
“…For our experiments, we developed a spectral-domain optical coherence tomography (OCT) scanner [22][23][24] and extra comp onents were integrated to simultaneously perform fluorescence imaging and patterned optogenetic stimulation (figure 1(a)) ( [13,25,26]).…”
Section: Methods: All-optical Interrogation Of Vascular Responsementioning
confidence: 99%
See 2 more Smart Citations
“…For our experiments, we developed a spectral-domain optical coherence tomography (OCT) scanner [22][23][24] and extra comp onents were integrated to simultaneously perform fluorescence imaging and patterned optogenetic stimulation (figure 1(a)) ( [13,25,26]).…”
Section: Methods: All-optical Interrogation Of Vascular Responsementioning
confidence: 99%
“…The implemented spectral-domain OCT scanner uses a low coherence light source (central wavelength 1300 nm, bandwidth >170 nm, total power 10 mW, Thorlabs, NJ, USA) and a 10x OCT objective lens (LSM02, Thorlabs, NJ, USA) to achieve axial and lateral resolutions of ∼4.4 μm and ∼5.1 μm, respectively [26]. A scan/tube lens mechanism is designed and used to open up the space before the back focal plane of the objective [25].…”
Section: Optical Setupmentioning
confidence: 99%
See 1 more Smart Citation
“…In SD-OCT, CCD, an array of photodetectors, measures interference signals in a range of specific frequency domain [ 18 ], [ 19 ]. The maximum amount of charges that a single pixel can store is defined as the full well capacity of a spectrometer [ 20 ].…”
Section: Methodsmentioning
confidence: 99%
“…An OCT system technology can be a timedomain OCT (TD-OCT) and frequency-domain OCT (FD-OCT). The main difference between the two is that the former uses a scanning mechanism to modulate the optical length of the reference path continuously and the intensity of the interference signal is maximum when the sample and reference path are equal, whereas the latter has a fixed mirror that generate images by analyzing the spectral pattern of the collected interferograms generated by combining the reflected lights from the reference and the sample arms [7].…”
Section: Introductionmentioning
confidence: 99%