1988
DOI: 10.1016/0021-9290(88)90004-8
|View full text |Cite
|
Sign up to set email alerts
|

Biomechanics of the arterial wall under simulated flow conditions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
10
0

Year Published

1989
1989
2009
2009

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 25 publications
(10 citation statements)
references
References 23 publications
0
10
0
Order By: Relevance
“…For example, because of the elevated pulse pressure, the change in internal vessel radius or vessel wall thickness (Fig. 4) measured during the simulation of tPP/tTP (7.1%) significantly exceeded that (2.7%) when normotension-t'TP conditions were imposed upon the test vessels (2,3). At the microscopic level, the increased motion of the vessel wall associated with these group III experiments may have "anchored" the EC to the underlying substratum as indicated by the EC shifting to a more polygonal shape ( Fig.…”
Section: Discussionmentioning
confidence: 93%
“…For example, because of the elevated pulse pressure, the change in internal vessel radius or vessel wall thickness (Fig. 4) measured during the simulation of tPP/tTP (7.1%) significantly exceeded that (2.7%) when normotension-t'TP conditions were imposed upon the test vessels (2,3). At the microscopic level, the increased motion of the vessel wall associated with these group III experiments may have "anchored" the EC to the underlying substratum as indicated by the EC shifting to a more polygonal shape ( Fig.…”
Section: Discussionmentioning
confidence: 93%
“…Immediately after euthanasia, the intact esophagus from seven animals in groups 3 and 4 was isolated and a custom clamping device [42] was used to maintain the in vivo length. The esophagus was excised in its entirety and was placed in lactated Ringer's solution at 4°C until time for testing (2Ϫ4 h).…”
Section: Pressure-diameter Responsesmentioning
confidence: 99%
“…The EVPS used in this study has gone through several design iterations to improve its functionality and diversity [3,39,[244][245][246][247]. The previous generation EVPS, upon which the current design was based, is shown schematically in Several other groups have designed specialized EVPSs for studying biochemical responses of blood vessel segments to imposed biomechanical stresses.…”
Section: The Concept Of Ex Vivo Perfusion Was Originally Investigatedmentioning
confidence: 99%
“…Our laboratory's well established, validated EVPS has been used for over two decades to study the mechanopathobiological responses of intact blood vessel segments to accurately simulated physiologic biomechanical signals [3,39,[244][245][246][247][248][249]. The EVPS used in this study has gone through several iterations to improve its functionality and is described in detail below.…”
Section: History Of Ex Vivo Vascular Perfusionmentioning
confidence: 99%
See 1 more Smart Citation