Background Although effective mental health treatments exist, the ability to match individuals to optimal treatments is poor, and timely assessment of response is difficult. One reason for these challenges is the lack of objective measurement of psychiatric symptoms. Sensors and active tasks recorded by smartphones provide a low-burden, low-cost, and scalable way to capture real-world data from patients that could augment clinical decision-making and move the field of mental health closer to measurement-based care. Objective This study tests the feasibility of a fully remote study on individuals with self-reported depression using an Android-based smartphone app to collect subjective and objective measures associated with depression severity. The goals of this pilot study are to develop an engaging user interface for high task adherence through user-centered design; test the quality of collected data from passive sensors; start building clinically relevant behavioral measures (features) from passive sensors and active inputs; and preliminarily explore connections between these features and depression severity. Methods A total of 600 participants were asked to download the study app to join this fully remote, observational 12-week study. The app passively collected 20 sensor data streams (eg, ambient audio level, location, and inertial measurement units), and participants were asked to complete daily survey tasks, weekly voice diaries, and the clinically validated Patient Health Questionnaire (PHQ-9) self-survey. Pairwise correlations between derived behavioral features (eg, weekly minutes spent at home) and PHQ-9 were computed. Using these behavioral features, we also constructed an elastic net penalized multivariate logistic regression model predicting depressed versus nondepressed PHQ-9 scores (ie, dichotomized PHQ-9). Results A total of 415 individuals logged into the app. Over the course of the 12-week study, these participants completed 83.35% (4151/4980) of the PHQ-9s. Applying data sufficiency rules for minimally necessary daily and weekly data resulted in 3779 participant-weeks of data across 384 participants. Using a subset of 34 behavioral features, we found that 11 features showed a significant (P<.001 Benjamini-Hochberg adjusted) Spearman correlation with weekly PHQ-9, including voice diary–derived word sentiment and ambient audio levels. Restricting the data to those cases in which all 34 behavioral features were present, we had available 1013 participant-weeks from 186 participants. The logistic regression model predicting depression status resulted in a 10-fold cross-validated mean area under the curve of 0.656 (SD 0.079). Conclusions This study finds a strong proof of concept for the use of a smartphone-based assessment of depression outcomes. Behavioral features derived from passive sensors and active tasks show promising correlations with a validated clinical measure of depression (PHQ-9). Future work is needed to increase scale that may permit the construction of more complex (eg, nonlinear) predictive models and better handle data missingness.
Abstract, Although there is considerable evidence to suggest that hemodynamics play an important role in vascular disease processes, the exact mechanisms are unknown. With this in mind, we have designed a pulsatile perfusion apparatus which reproducibly delivers pulsatile hemodynamics upon freshly excised canine carotid arteries in vitro. Quantifiable simulations included (a) normotension with normal or lowered flow rates (120/80 mmHg, 120 and 40 ml/min), (b) normotension with lowered or elevated transmural pressures (40-170 mmHg), and (c) elevated pulse pressure (120 and 80 mmHg) with normal (150 ml/min) or elevated rates of flow (300 and 270 ml/min). Arterial biomechanical stresses and cellular behaviors were characterized biochemically and morphologically under all these simulations which continued for 2-24 h. We found that increased pulse pressure alone had little effect on the total amount of radiolabeled [4-J4C]cholesterol present within the medial compartment. However, normotension when coupled with altered transmural pressure yielded a three-to fourfold increase.Combinations of increased pulse pressure and flow potentiated cholesterol uptake by a factor of 10 when compared with normotension control values. Simulations that enhanced carotid arterial cholesterol uptake also influenced the endothelial cytoskeletal array of actin. Stress fibers were not present within the carotid endothelial cells of either the sham controls or the normotension and increased pulse pressure (normal flow) simulations. Endothelial cells lining carotids exposed to elevations in flow or those present within vessels perfused as per simulation b above assembled stress fibers (x = 4 and 10 per cell, respectively) within the time course of these studies. When endothelial cells were subjected to hemodynamic conditions that potentiated maximally cholesterol transport, no diffuse or stress fiber staining could be seen, but the cortical array of actin was intact. These results suggest that those biomechanical stresses that alter endothelial permeability and intimal integrity may do so via cytoskeletal actin signaling.ECENT experimental evidence indicates that endothelial cells (EC), 1 which line the blood vascular systems of higher vertebrates, are actively involved in maintenance of intimal integrity. This stabilization against the blood shearing forces and biomechanical wall stresses at the luminal-EC interface may be directly related to the intimal cells' ability to synthesize and organize (a) junctional elements, (b) materials of the basal laminae that promote EC adhesion to the extracellular matrix, and (c) an intricate cytoskeleton composed of contractile and structural proteins needed to modulate the luminal-abluminal shear zone.Early work in vitro revealed that vascular EC possessed linear cytoplasmic fibrils (16). Naming the structures "tension striae" the Lewises proposed that these elements (later renamed "stress fibers") promoted adhesion of cells to the underlying substrate. A structural rather than motile role for stress fi...
A noncontacting in vitro measurement of pulsatile arterial diameter using a scanning optical micrometer is described. The major component of this system is a He-Ne laser whose beam scans the pulsating artery to be measured. The laser micrometer was integrated into a pulsatile perfusion apparatus that imposed various hemodynamic conditions on excised canine vessels. The laser system reliably tracked the pulsating arterial diameter at a particular longitudinal site as well as at various increments in the presence of an experimentally created stenosis. The He-Ne laser measured the radial motion of canine arteries and various vascular substitutes anastomosed in an end-to-end fashion. From these novel measurements, calculations were made of arterial compliance and bending stress, two biomechanical parameters that are implicated as potential causes of anastomotic intimal hyperplasia and graft failure. Although this device is inherently limited to in vitro use, it is a potentially useful instrument for vascular physiology and biophysics.
Chronic, subclinical retinal detachments may rarely be associated with retinal macrocysts and retinal neovascularization. This altered retinal morphology can be delineated on wide-field fundus imaging, which aids in diagnosis and management.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.